Loading...
Agenda - Committee of Adjustment - 20241212Town of Aurora Committee of Adjustment Meeting Agenda Date:Thursday, December 12, 2024 Time:7 p.m. Location:Video Conference Meetings are available to the public via live stream on the Town’s YouTube channel. To participate electronically, please visit aurora.ca/participation. Pages 1.Call to Order 2.Land Acknowledgement 3.Approval of the Agenda That the Agenda as circulated by the Secretary-Treasurer be approved. 4.Declarations of Pecuniary Interest and General Nature Thereof 5.Receipt of the Minutes 5.1 Committee of Adjustment Meeting Minutes of November 14th, 2024, Meeting Number 24-11 1 That the Committee of Adjustment Minutes from Meeting Number 24-11 be adopted as printed and circulated. 6.Presentation of Applications 6.1 MV-2024-31 - Duff - 47 Cousins 8 6.2 MV-2024-28 - Risk - 15 Tyler St 20 7.New Business 8.Adjournment 1 Town of Aurora Committee of Adjustment Meeting Minutes Date: Time: Location: Thursday, November 14, 2024 7 p.m. Video Conference Committee Members: David Mhango (Chair) Chris Polsinelli Jane Stevenson (Vice Chair) Michael Visconti Julian Yang Other Attendees: Peter Fan, Secretary-Treasurer, Committee of Adjustment Antonio Greco, Senior Planner _____________________________________________________________________ 1. Call to Order That the meeting be called to order at 7:01PM. 2. Land Acknowledgement The Town of Aurora acknowledges that the Anishinaabe (A-nishshaw-na-bee) lands on which we live, and work are the traditional and treaty territory of the Chippewas of Georgina Island, as well as many other Nations whose presence here continues to this day. As the closest First Nation community to Aurora, we recognize the special relationship the Chippewas have with the lands and waters of this territory. They are the water protectors and environmental stewards of these lands, and as a municipality we join them in these responsibilities. We further acknowledge that Aurora is part of the treaty lands of the Mississaugas and Chippewas, recognized through Treaty #13 as well as the Williams Treaties of 1923. Page 1 of 40 2 A shared understanding of the rich cultural heritage that has existed for centuries, and how our collective past brought us to where we are today, will help us walk together into a better future. 3. Approval of the Agenda Moved by Julian Yang Seconded by Jane Stevenson That the Agenda as circulated by the Secretary-Treasurer be approved. Carried 4. Declarations of Pecuniary Interest and General Nature Thereof None. 5. Receipt of the Minutes 5.1 Committee of Adjustment Meeting Minutes of October 10, 2024, Meeting Number 24-10 Moved by Michael Visconti Seconded by Jane Stevenson That the Committee of Adjustment Minutes from Meeting Number 24-10 be adopted as printed and circulated. Carried 6. Presentation of Applications 6.1 C-2024-04, C-2024-05 - Allan- 2 Willow Farm Lane The applicant is requesting provisional consent to sever the subject lands to create one new residential lot containing a single detached dwelling fronting onto Willow Farm Lane. The purposes of the proposed consent applications are to: A. Create one (1) new lot fronting onto Willow Farm Lane (severed lot). The retained lot will front onto St. John’s Sideroad (C-2024-04) B. Establish a 6.0-metre-wide servicing easement on the severed lot in favour of the retained lot (C-2024-05) Page 2 of 40 3 The Chair invited the Applicant or Owner to address the Committee. In attendance was the agent Joshua Morgan. The agent provided a brief introduction and presentation to their application. The Chair invited members of the public to provide comments. There were no public delegates in attendance for this application. The Committee inquired about the purpose of the proposed servicing easement as well as any foreseeable issues, given that the proposed footprint of the dwelling is in close proximity of the proposed easement. The Committee also inquired about the address that the retained parcel will receive as the new access will be located off of St. John's Sideroad. Moved by Chris Polsinelli Seconded by Jane Stevenson That the Consent Applications C-2024-04 and C-2024-05 be APPROVED. Carried 6.2 MV-2024-01 - Liu - 2007 Vandorf Sideroad The owner/applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the construction of a new two (2) storey detached dwelling. The following relief is being requested: 1. Section 18.1.3 of the Zoning By-law states new single residential dwellings on existing lots will only be permitted through a minor variance. The applicant is proposing to construct a new two-storey detached dwelling; and, 2. Section 14.1.3(i) of the Zoning By-law states no development or site alteration shall occur on that portion of the lot that contains a minimum vegetation protection zone. The applicant is proposing to construct a two-storey detached dwelling; and, 3. Section 4.20 of the Zoning By-law states canopies may project 0.7 metres into any required yard. The applicant is proposing to construct a two-storey detached dwelling, with canopies projecting 1.5 metres into the required front yard; and, Page 3 of 40 4 The Chair invited the Applicant or Owner to address the Committee. In attendance was the agent, Christine Deng. The agent provided a brief introduction and presentation to their application. The Chair invited members of the public to provide comments. There were no public delegates in attendance for this application. The Committee had no comments or concerns with the application. Moved by Michael Visconti Seconded by Julian Yang That the Minor Variance application MV-2024-01 be APPROVED. Carried 6.3 MV-2024-29 - Birkland- 7 Johnson Rd The owner/applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the construction of a detached garage. The following relief is being requested: 1. Section 24.497.8 of the Zoning By-law permits a maximum gross floor area of 40.0m2 (430.5 ft2). The applicant is proposing a detached garage with a gross floor area of 45.0 m2 (484.4 ft2). The Chair invited the Applicant or Owner to address the Comm ittee. In attendance was the agent David Eqbal. The agent provided a brief introduction and to their application. The Chair invited members of the public to provide comments. There were no public delegates in attendance for this application. The Committee had no comments or concerns for the application. Moved by Jane Stevenson Seconded by Julian Yang That the Minor Variance application MV-2024-29 be APPROVED Carried 6.4 MV-2024-30 - Butler - 81 Tyler St Page 4 of 40 5 The owner is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the construction of a two (2) storey detached garage and associate private driveway off George Street. The following relief is being requested: 1. Section 4.1.2 (b) of the Zoning By-law permits a maximum height of 4.5 metres. The applicant is proposing a detached garage with a height of 6.2 metres. 2. Section 5.6.1 (c) of the Zoning By-law states only one driveway access point shall be permitted for each residential lot. The applicant is proposing a second driveway access point on George Street. 3. Section 5.6.1(a)(ii) of the Zoning By-law permits a maximum driveway width of 6.0 metres if the lot frontage is greater than or equal to 9.0 metres and less than 18.0 metres. The applicant is proposing a driveway width of 7.4 metres. The Chair invited the Applicant or Owner to address the Committee. In attendance was the agent Chris Pretotto and owner David Butler. The agent the owner provided a brief introduction and presentation to their application. The Chair invited members of the public to provide comments. There was one (1) public delegate in attendance for this application - Joanna Stricker. Joanna expressed her concerns in opposition of the application, citing issues of density, size, and height. The Committee had concerns regarding the second driveway on the property, citing future compliances for a corner lot. Staff responded and clarified that through the review of the application, there is no concerns. The committee also inquired about the height of the structure and servicing on site for the proposed. Moved by Julian Yang Seconded by Jane Stevenson That the Minor Variance application MV-2024-30 be APPROVED Carried 6.5 MV-2024-21 - Ahmad - 45 Steeplechase Ave Page 5 of 40 6 The owner/applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the constriction of a two-storey detached dwelling. The following relief is being requested: 1. Section 7.2 of the Zoning By-law requires a maximum building height of 10 metres. The applicant is proposing to construct a two- storey detached dwelling, which is 10.6 metres. 2. Section 14.1.2(ii) of the Zoning By-law states no site alteration shall occur on that portion of said lot that is within the f eature, without an amendment to, or relief from the Zoning By-law. The applicant is proposing to construct a two-storey detached dwelling. 3. Section 14.1.3(i) of the Zoning By-law states no development or site alteration shall occur on that portion of the lot that contains a minimum vegetation protection zone, without an amendment to, or relief from the Zoning By-law. The applicant is proposing to construct a two-storey detached dwelling. 4. Section 14.1.4(i) of the Zoning By-law states no development or site alteration shall occur on that portion of the lot that contains a significant woodland, without amendment to, or relief from the Zoning By-law. The applicant is proposing to construct a two-storey detached dwelling. The Chair invited the Applicant or Owner to address the Committee. In attendance was the agent Paul Mariani. The agent provided a brief introduction to their application. The Chair invited members of the public to provide comments. There were no public delegates in attendance for this application. The Committee inquired about why the applicant proceeded without the proper building permits. The committee also inquired if the decision of the application would impact the provincial offences matter. Staff clarified that there would be no impact on the current application. Moved by Michael Visconti Seconded by Jane Stevenson That the Minor Variance application MV-2024-21 be APPROVED. Page 6 of 40 7 Carried 7. New Business None. 8. Adjournment Moved by Julian Yang That the meeting be adjourned at 8:23PM. Carried Page 7 of 40 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 4 -31 _______________________________________________________________________________________ Subject: Minor Variance Application Lisa Wilson Duff 47 Cousins Drive PLAN 340 PT LOT 35 & 36 File: MV-2024-31 Prepared by: Felix Chau, Planner Department: Planning and Development Services Date: December 12, 2024 _______________________________________________________________________________________ Application The owner/applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate a rear addition to an existing detached dwelling. The following relief is being requested: a) Section 24.497.3.2 of the Zoning By-law requires a minimum rear yard of 25% of the lot depth, which is 11.43 metres. The applicant is proposing a one -storey addition, covered porch and deck, which is 9.8 metres to the rear property line. b) Section 24.497.3.2 of the Zoning By-law requires a minimum interior side yard of 3.0 metres beyond the main rear wall of the adjacent dwelling. The applicant is proposing a one-storey addition, covered porch and deck which is 1.4 metres to the interior side property line. c) Section 24.497.3.2 of the Zoning By-law requires a minimum interior side yard setback of 1.5 metres. The applicant is proposing a one-addition, covered porch and deck which is 1.4 metres to the interior side property line. Page 8 of 40 December 12, 2024 2 of 8 Report No. MV-2024-31 Background Subject Property and Area Context The subject lands are municipally known as 47 Cousins Drive and it is located on the south side of Cousins Drive, east of Yonge Street. The subject lands have an approximate lot area of 1045.2 square metres (11,250 square feet) and an approximate lot frontage of 22.9 metres (75 feet). A two-storey detached dwelling is currently featured on the lands which will remain as part of this proposal. Proposal The applicant is proposing to construct a one-storey addition, covered porch, and deck to the rear of the existing two-storey detached dwelling. The proposed addition is 86.86 square metres (935 square feet) in size and is intended for a secondary dwelling unit. The proposed covered porch is 10.89 square metres (117.2 square feet), and the proposed deck is 9.74 square metres (104.8 square feet) and are both accessed from the proposed addition. Bill 23 – the Mores Homes Built Faster Act Bill 23 amended the Planning Act to permit additional residential units as-of-right across the province. The intent of the legislation is to assist the province in meeting planned minimum housing and density targets. Additional residential units are specifically seen as assisting with creating housing opportunities through the gentle intensification of traditionally lower density residential areas. Landowners are now permitted as-of-right to add additional residential units on properties containing a single detached dwelling, semidetached dwelling, or a townhouse. The provincial additional residential unit framework under Bill 23 supersedes local official plans and zoning province wide for the use. Official Plan The subject property is designated ‘Stable Neighbourhoods’ by the Town of Aurora Official Plan. This designation permits the development of single detached dwellings subject to the development policies of the Official Plan. Page 9 of 40 December 12, 2024 3 of 8 Report No. MV-2024-31 Zoning The subject lands are zoned R3-SN (497) (Detached Third Density Residential Exception Zone) by the Town of Aurora Zoning By-law #6000-17, as amended, where Detached Dwelling is listed as a permitted use. Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town of Aurora’s Building Division. The PZR identified the required variances and no other non-compliance was identified. Applicant’s stated reason(s) for not complying with the Zoning By-law As stated on the application form, the applicant is seeking relief from the Zoning By-law to create enough livable space for a comfortable secondary unit and to create a covered entrance to the secondary dwelling. Planning Comments Planning Staff have evaluated Minor Variance Application MV-2024-31 pursuant to the prescribed tests as set out in Section 45 (1) of the Planning Act, as follows: a) The proposed variance meets the general intent of the Official Plan The subject lands are designated ‘Stable Neighbourhoods’ under the Town of Aurora’s Official Plan. The intent of the ‘Stable Neighbourhoods’ designation is to ensure that all new development will be protected from incompatible forms of development. The designation permits ground-oriented residential development, which includes detached dwellings, and focuses on ensuring new development is designed in an appropriate and high-quality manner to enhance the streetscape. The underlying priority is for new development and infill housing opportunities to be introduced in a complementary manner, particularly from an architectural design and compatibility perspective. To assist infill developments to be compatible with the exiting neighbourhood, a Stable Neighbourhood Design Guidelines was developed. The proposed dwelling has been reviewed with guidance from the Stable Neighbourhoods Design Guidelines. The exterior of the proposed addition maintains the same architectural material as the existing detached dwelling, as such, it will preserve the look of a single detached dwelling on the lot. Staff are of the opinion that the requested Page 10 of 40 December 12, 2024 4 of 8 Report No. MV-2024-31 variances will not have an impact towards the local streetscape as the requested addition is in the rear of the existing detached dwelling. Staff are of the opinion that the proposed development meets the applicable policies an maintains the general intent and purpose of the Official Plan. b) The proposed variance meets the general intent of the Zoning By-law Minimum Rear Yard Lot Depth The intent of the minimum rear yard lot depth provision of the Zoning By-law is to ensure that there is adequate space for outdoor amenity area, privacy, access and drainage. The Zoning By-law requires a minimum rear yard of 25% of the lot depth, which is 11.43 metres (37.5 feet) whereas the requested variance contemplates a minimum rear yard setback of 9.8 metres (32.2 feet). As such, the proposed addition encroaches into the minimum required rear yard by 1.63 metres. The proposed addition is 86.86 square metres (935 square feet) in size, representing 8.3% of the total lot area. Furthermore, the width of the proposed addition which encroaches into the minimum required rear yard is 6.0 metres (19.6 feet), whereas the existing detached dwelling has an approximate width of 17.2 metres (57.8 feet). As such, in conjunction with the one- storey nature of the proposed addition, the requested variance will not result in the overdevelopment of the site or impose any negative massing impacts towards the neighbouring properties. Staff are of the opinion that impacts related to overlook and privacy to the neighbouring property will be minimal, given there are minimal windows proposed on the westerly wall of the addition. As such, the proposed addition meets the intent of the rear yard lot depth provision of the Zoning By-law, as sufficient space for outdoor amenity area, privacy, access and drainage is maintained. Minimum Interior Side Yard Setback There are two provisions within the Zoning By-law pertaining to the minimum interior side yard setback which require variances to facilitate the proposed addition. The By-law establishes a minimum interior side yard of 3.0 metres beyond the main rear wall of the adjacent dwelling and a minimum interior side yard setback of 1.5 metres. Page 11 of 40 December 12, 2024 5 of 8 Report No. MV-2024-31 The intent of both side yard setback provisions is to ensure appropriate and adequate spacing for landscaping, access, drainage and to promote a level of openness and privacy between neighbouring properties and reduce overdevelopment of the site. Although the proposed addition has a reduced side yard setback of 1.4 metres, the addition itself is modest in its overall mass as it is a one-storey addition (3.8 metres in height), whereas the existing dwelling is two-storeys (6.4 metres in height), thus resulting in minimal visual obstruction and impact. The proposed addition is intended to be used as a secondary dwelling unit. The requested reduction to the side yard setback will result in minimal impacts, as it relates to building separation to the adjacent properties. The proposed side yard reductions still provide for adequate access to the rear yard and does not have an impact on maneuverability. Engineering staff have also reviewed and have no objections with the structure in regard to drainage concerns. c) The proposed variance is considered desirable for the appropriate development of the land The minor variance has been considered in the context of the site itself and the adjacent neighbourhood. The proposed addition has been designed in a manner that respects the existing neighbourhood and adjacent neighbour. The requested variance will also enable the existing dwelling to expand their indoor living area while maintaining ample amenity area and backyard green space. The proposed one storey addition provides sufficient room for access, drainage, and maneuverability along the westerly side yard. The overall impact of the design is proportional to the lot size and the addition has been designed in a manner that respects neighbourhood privacy and spacing. The proposal allows for the appropriate development of the site to accommodate an addition for a secondary dwelling unit and is done so in a manner that in the opinion of staff respects the existing neighbourhood character. The streetscape is unaltered as the addition is located to the rear of the property, while the character of the neighbourhood is maintained as the addition will not generate any streetscape concerns relating to its overall massing and scale. As such, the requested variance is considered desirable for the appropriate development of the land. d) The proposed variance is considered minor in nature The question of the minor nature of a proposed variance can be related to its scale and impact on adjacent properties. In the opinion of staff, the requested variances are considered to be minor and are not expected to have any adverse effects on the subject lands, neighbouring properties, or the character of the existing mature neighbourhood as Page 12 of 40 December 12, 2024 6 of 8 Report No. MV-2024-31 a whole. Staff are of the opinion that impacts related to overlook and privacy to the neighbouring property will be minimal, given there are minimal windows proposed on the westerly wall of the addition in addition to existing vegetative screening that will remain on site. Staff are of the opinion that the requested variance is minor in nature. Additional Comments The minor variance application was circulated to Town Department/Divisions and to external agencies for review and comment. The following comments were provided: Department or Agency Comments Building Division Preliminary Zoning Review was completed. No objections. Engineering Division No objections. Operational Services (Parks) No objections. Operational Services (Public Works) No objections. Central York Fire Services No objections. York Region No objections. LSRCA No objections. Public Correspondence Written submissions were not received at the time of writing of this report. Should written submissions be received after the writing of this report, the Secretary Treasurer will provide the submission(s) to Committee members at the meeting. Conclusion Planning staff have reviewed the application with respect to the Section 45 (1) of the Planning Act, R.S.O, 1990, c.P.13, as amended, and are of the opinion that the requested variances meet the four tests the Planning Act for granting of minor variances. Please refer to Appendix ‘A’ for recommended conditions of approval for the requested variance. Page 13 of 40 December 12, 2024 7 of 8 Report No. MV-2024-31 Attachments Appendix ‘A’ – Recommended Conditions of Approval Appendix ‘B’ – Site Plan Appendix ‘C’ – Elevations Page 14 of 40 December 12, 2024 8 of 8 Report No. MV-2024-31 Appendix ‘A’ – Recommended Conditions of Approval The following conditions are required to be satisfied should application MV-2024-31 be approved by the Committee of Adjustment: 1. That the variance only applies to the subject property, in conformity with the plan(s) attached as ‘Appendix B’ to this Staff Report, to the satisfaction of the Director of Planning and Development Services or designate. Page 15 of 40 UP2.1 m7' - 0"6.1 m20' - 0"9.8 m32' - 2 1/4"17.9 m58' - 7 3/4"18.2 m59' - 7"1.4 m4' - 7"22.9 m75' - 0" LOT LINE45.8 m150' - 5" LOT LINE6.0 m19' - 9"COVERED PORCH (117.2sq/ft) 10.89m2ADDITION (935sq/ft) 86.86m2DECK(104.8sq/ft) 9.74m2COVERED WRAP AROUND (548sq/ft) 50.9m2EXISTING RESIDENCE (1300sq/ft) 120.77m212.0 m39' - 6"LOT (11250sq/ft) 1045.15m2DECK -0.9%ADDITION -8.3%COVERED PORCH BACK -1.0%COVERED WRAP AROUND -4.9%EXISTING RESIDENCE -11.6%TOTAL COVERAGE = 26.7%7.0 m23' - 1 1/2"4.6 m14' - 11 1/4"4.8 m15' - 9"11.6 m38' - 0 3/4"2.2 m7' - 3 3/4"15.3 m50' - 4"50.0 m164' - 0"3.5 m11' - 7"N10.3 m+/- 33' - 11 1/4"RESIDENCERESIDENCERESIDENCECOUSINS DRIVE7.6 m+/- 24' - 9 3/4"10.1 m+/- 33' - 2"6.8 m+/- 22' - 2 3/4"1.2 m+/- 3' - 10 1/2"PROJECT #:PLOT DATE:PROJECT ADDRESS:THE UNDERSIGNED HAS REVIEWED & TAKES RESPONSIBILITY FOR THIS DESIGN, & HAS THE QUALIFICATIONS & MEETS THE REQUIREMENTS SET OUT IN THE ONTARIO BUILDING CODE TO DESIGN THE WORK SHOWN ON THE ATTACHED DOCUMENTSQUALIFICATION INFORMATIONREQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.5.1 OF THE BUILDING CODEDANA EVANS100332NAME BCINREGISTRATION INFORMATIONREQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.4.1 OF THE BUILDING CODE209 DESIGN101521FIRM NAMEBCIN2 0 9 D E S I G N www.209design.ca1 5 9 0 5 S I D E R D . 1 7 , S U N D E R L A N D O N L 0 C 1 H 06 4 7 - 2 9 7 - 8 3 0 0 D A N A @ 2 0 9 D E S I G N . C A Oct 30 2024A1.01SITE PLAN47 Cousins DriveAurora, ON24-0101 : 200Site Plan1Number Description Date0 Preliminary Review Sept 25 20241 Minor Variance Application Oct 30 2024PR20241187 Oct. 31, 2024 TOWN OF AURORA PLANNING & DEVELOPMENT SERVICES BUILDING DIVISION PERMIT NO.: DATE: PRELIMINARY ZONING REVIEW APPROVED BY: Melissa Bozanin Page 16 of 40 Main Floor 0' -0" 2nd Floor 8' -7 3/8" Top of Basement -1' -0" 2nd Ceiling 15' -10" Garage Ceiling -1' -0 1/2"Addition Site Plan -1' -11"6:126:123.8 m12' - 6 3/4"4.5 m14' - 7 1/4"Garage -10' -0" Main Floor 0' -0" 2nd Floor 8' -7 3/8" Top of Basement -1' -0" 2nd Ceiling 15' -10" Addition Site Plan -1' -11"2.67:1212' - 0"9' - 2"12' - 0"7' - 6 3/4" 4' - 7"4' - 7" EQ EQ EQ EQ4.6 m15' - 2 3/4"PROJECT #: PLOT DATE: PROJECT ADDRESS:THE UNDERSIGNED HAS REVIEWED & TAKES RESPONSIBILITY FOR THIS DESIGN, & HAS THE QUALIFICATIONS & MEETS THE REQUIREMENTS SET OUT IN THE ONTARIO BUILDING CODE TO DESIGN THE WORK SHOWN ON THE ATTACHED DOCUMENTS QUALIFICATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.5.1 OF THE BUILDING CODE DANA EVANS 100332 NAME BCIN REGISTRATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.4.1 OF THE BUILDING CODE 209 DESIGN 101521 FIRM NAME BCIN 2 0 9 D E S I G N www.209design.ca 1 5 9 0 5 S I D E R D . 1 7 , S U N D E R L A N D O N L 0 C 1 H 0 6 4 7 - 2 9 7 - 8 3 0 0 - D A N A @ 2 0 9 D E S I G N . C A Sept 25 2024 A201 ELEVATIONS 47 Cousins Aurora, ON 24-010 1/8" = 1'-0" South Elevation2 1/8" = 1'-0" North Elevation1 Number Description Date 0 Concepts Aug 5 2024 1 Revision Aug 28 2024 2 Quote pg Sept 16 2024 3 Preliminary Review Sept 25 2024 PR20241187 Oct. 31, 2024 TOWN OF AURORA PLANNING & DEVELOPMENT SERVICES BUILDING DIVISION PERMIT NO.: DATE: PRELIMINARY ZONING REVIEW APPROVED BY: Melissa Bozanin Page 17 of 40 Ext. Grade -1' -11" Main Floor 0' -0" 2nd Floor 8' -7 3/8" Top of Basement -1' -0" 2nd Ceiling 15' -10" Garage Ceiling -1' -0 1/2"Addition Site Plan -1' -11" 6 :1 2 Ext. Grade -1' -11" Main Floor 0' -0"Top of Basement -1' -0" 2nd Ceiling 15' -10" Addition Site Plan -1' -11"7' - 5 1/2"7' - 3 1/8"7' - 3 1/8"7' - 3 1/8"7' - 3 1/8"3:123:123:124:124.5:12PROJECT #: PLOT DATE: PROJECT ADDRESS:THE UNDERSIGNED HAS REVIEWED & TAKES RESPONSIBILITY FOR THIS DESIGN, & HAS THE QUALIFICATIONS & MEETS THE REQUIREMENTS SET OUT IN THE ONTARIO BUILDING CODE TO DESIGN THE WORK SHOWN ON THE ATTACHED DOCUMENTS QUALIFICATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.5.1 OF THE BUILDING CODE DANA EVANS 100332 NAME BCIN REGISTRATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.4.1 OF THE BUILDING CODE 209 DESIGN 101521 FIRM NAME BCIN 2 0 9 D E S I G N www.209design.ca 1 5 9 0 5 S I D E R D . 1 7 , S U N D E R L A N D O N L 0 C 1 H 0 6 4 7 - 2 9 7 - 8 3 0 0 - D A N A @ 2 0 9 D E S I G N . C A Sept 25 2024 A202 ELEVATIONS 47 Cousins Aurora, ON 24-010 1/8" = 1'-0" East Elevation1 1/8" = 1'-0" West Elevation2 Number Description Date 0 Concepts Aug 5 2024 1 Revision Aug 28 2024 2 Quote pg Sept 16 2024 3 Preliminary Review Sept 25 2024 Page 18 of 40 PROJECT #: PLOT DATE: PROJECT ADDRESS:THE UNDERSIGNED HAS REVIEWED & TAKES RESPONSIBILITY FOR THIS DESIGN, & HAS THE QUALIFICATIONS & MEETS THE REQUIREMENTS SET OUT IN THE ONTARIO BUILDING CODE TO DESIGN THE WORK SHOWN ON THE ATTACHED DOCUMENTS QUALIFICATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.5.1 OF THE BUILDING CODE DANA EVANS 100332 NAME BCIN REGISTRATION INFORMATION REQUIRED UNLESS DESIGN IS EXEMPT UNDER DIV. C -3.2.4.1 OF THE BUILDING CODE 209 DESIGN 101521 FIRM NAME BCIN 2 0 9 D E S I G N www.209design.ca 1 5 9 0 5 S I D E R D . 1 7 , S U N D E R L A N D O N L 0 C 1 H 0 6 4 7 - 2 9 7 - 8 3 0 0 - D A N A @ 2 0 9 D E S I G N . C A Sept 25 2024 A209 RENDERINGS 47 Cousins Aurora, ON 24-010 3D View 11 3D View 32 3D View 173 Number Description Date 0 Concepts Aug 5 2024 1 Revision Aug 28 2024 2 Quote pg Sept 16 2024 3 Preliminary Review Sept 25 2024 Page 19 of 40 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 4 -28 _______________________________________________________________________________________ Subject: Minor Variance Application Andrew Risk 15 Tyler Street PLAN 9 PT LOTS 7 AND 8 AND RP 65R25427 PART 1 File: MV-2024-28 Prepared by: Antonio Greco, Senior Planner Department: Planning and Development Services Date: December 12, 2024 _______________________________________________________________________________________ Application The applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the construction of a five-storey mixed use building with at grade office and five residential units above. The vehicular access is off Temperance Street, with parking at rear. The following relief is being requested: a) Section 8.2 of Zoning By-law 6000-17 permits a maximum height of 10 meters. The applicant is proposing a five-storey residential building containing a maximum height of 20 metres. b) Section 5.4 of Zoning By-law 6000-17 requires parking for offices at a rate of 3.5 spaces per 100 square meters of Gross Floor Area and 1.5 spaces per dwelling unit, with a minimum 20% of spaces provided to be set aside for visitor parking. Therefore 10 parking spaces inclusive of a barrier free parking space is required. The applicant is proposing a total of seven (7) parking spaces inclusive of the barrier free space. Background Subject Property and Area Context The subject property is located at the southeast corner of Temperance Street and Tyler Street, approximately 87 m (285 ft) west of Yonge Street. The subject property has an Page 20 of 40 December 12, 2024 2 of 11 Report No. MV-2024-28 area of roughly 399.22 m2 (4297.16 ft2) and a frontage of approximately 12.66 m (41.53 ft) on Tyler Street and 31.76 m (104.19 ft) on Temperance Street. The subject property contains a one-storey detached dwelling, which is currently listed on the Town of Aurora Register of Properties of Cultural Heritage Value or Interest. Proposal The applicant is proposing to demolish the existing one-storey detached dwelling on the subject property and facilitate the construction of a five-storey mixed use building, containing an office on the ground floor, with five residential units above. Application History The minor variance application was first presented to the Committee of Adjustment during the meeting on October 10, 2024. The Committee voted to defer the application, giving the applicant an opportunity to provide further evidence that the proposed development can meet the daylighting triangle requirements. The design of the proposed mixed-use building has been updated from its original plan to include a larger front yard setback of 1.8 meters, compared to the previous 0.14-meter setback. Additionally, the ground floor office space has been redesigned to feature an angular wall to improve traffic and pedestrian sightlines at the Tyler Street and Temperance Street intersection. Official Plan The subject property is designated within the “Aurora Promenade and MTSA Mixed Use” on Schedule ‘B’ – Land Use Plan by the Town of Aurora Official Plan and specifically designated as “Downtown” within Schedule ‘D1’ - The Aurora Promenade and Major Transit Station Area Secondary Plan Area. This designation is intended to accommodate a mixture of uses such as dwelling units located on the second storey, and/or above all building types and commercial/institutional uses. Zoning The Subject property is zoned “PD1 – Promenade Downtown” under Zoning By-law 6000- 17, as amended. This zoning permits for a wide range of uses, including dwelling units above the first storey and a variety of commercial, retail and institutional uses. Page 21 of 40 December 12, 2024 3 of 11 Report No. MV-2024-28 Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town of Aurora’s Building Division. The PZR identified the required variances, and no other non-compliance was identified. Applicant’s stated reason(s) for not complying with the Zoning By-law As stated in the application form, “the applicant seeks to provide rental units with the increased maximum height of the proposed building.” Planning Comments Planning staff have evaluated Minor Variance Application MV-2024-28 pursuant to the prescribed tests as set out in Section 45 (1) of the Planning Act, as follows: a) The proposed variance meets the general intent of the Official Plan The subject property is designated “Downtown” by the Town of Aurora Official Plan. This designation is intended to guide development, while protecting and reinforcing a heritage ‘main street’ character and identity. The careful regulation of land uses and control over the scale and placement of infill structures is required to enhance the pedestrian experience, while still allowing for and promoting increased density in keeping with the character and scale of the Downtown. A mixture of uses is encouraged not just within this designation in general, but also on individual development sites, and within individual buildings. As mentioned previously, the existing one-storey dwelling is currently a listed property on the Heritage Registry. As part of the application circulation, a preliminary review was conducted on the building’s cultural heritage significance, which demonstrated a minimal value. That said, a condition of approval has been developed that requires the owner/applicant to obtain the necessary clearance from Town of Aurora Council to remove (delist) the property from the Town's Heritage Registry. Consultation will also be required to occur with the Town's Heritage Advisory Committee (HAC), with the submission of a Cultural Heritage Evaluation Report demonstrating support. Furthermore, properties within the Aurora Promenade and Major Transit Station Area contain specific minimum and maximum building heights. The subject property permits a maximum of five (5) storeys as per Schedule D-2 of the Official Plan. The proposed construction of a five-storey mixed use building and rear yard parking lot complies with the permitted uses, development policies and the building height provisions of the Official Plan. Development within the Aurora Promenade is to accommodate a broad Page 22 of 40 December 12, 2024 4 of 11 Report No. MV-2024-28 range of choices for travel. Yonge Street and Wellington Street will accommodate transit, cyclists, pedestrians, as well as cars through a complete streets approach. Overall, Staff are therefore of the opinion that the proposed variances meet the general intent of the Official Plan. b) The proposed variance meets the general intent of the Zoning By-law The Subject property is zoned “Promenade Downtown (PD1)” under Zoning By-law 6000- 17, as amended. The intent of this zoning is to provide a wide variety of residential, commercial and institutional uses, while focusing on growth and intensified development, accommodating the highest densities within Aurora. A summary of the variances requested and how they meet the general intent of the zoning is as follows: Maximum Building Height: The intent of the building height provision is to ensure that development is designed in a consistent manner with no singular buildings negatively impacting or dominating the downtown streetscape. The uniform pattern along the Aurora Promenade is to provide an attractive streetscape while maximizing the potential of individual residential lots. The Official Plan and Zoning By-law function concurrently to ensure the appropriate development of specific areas and individual lots in Town. As mentioned earlier in this report, the proposed building height is in line with the provisions of the Official Plan and the “Downtown” designation, which allows for a minimum of two (2) storeys and a maximum of five (5) storeys. The Town has commenced the comprehensive review of the Zoning By-law, which will review and update areas in Town that don’t align amongst both policy documents. The Aurora Promenade and Major Transit Station Area is an identified area that requires review of the baseline maximum height provisions. Furthermore, the proposed minor variance to increase the maximum height is required, as the Town’s Comprehensive Zoning By-law 6000-17 currently reflects a base line maximum of 10 metres and has not been updated to align its current standards to what is currently permitted from an Official Plan standpoint. Section 8.2 of the Zoning By-law provides a breakdown of the maximum heights within the Promenade Zones. There is an exception in the PD1 Zone that permits for a maximum height of 18.5 metres, provided the 4th and 5th storeys are setback a minimum of 3 m from the main and exterior side walls of the 3rd storey. When taking this into consideration, the increase from 18.5 metres to 20 metres is minor and meets the intent of the Zoning By-law. In addition, when evaluating the maximum height for apartment buildings, there is always a height range between 3.0 metres to 4.0 metres per storey. This range is dependent of whether there are residential or retail units of the ground floor, which can Page 23 of 40 December 12, 2024 5 of 11 Report No. MV-2024-28 provide a range of ceiling heights between 8 feet to 10 feet and whether residential units above the ground floor are providing lofts. Given this 3.0 metres to 4.0 metres per storey range, a five-storey building can be anywhere from 15 metres to 20 metres. Even at its absolute lowest, a minor variance application would have been required. Provided all this information, Staff are of the opinion that the proposed maximum height continues to meet the general intent of the Zoning By-law and provides an attractive rental housing product to the neighbourhood. Minimum Parking: The intent of the minimum parking space requirement is to ensure that sufficient parking spaces are provided to meet the needs of the proposed residential building, and that vehicle spillover will not occur for overcrowding of the subject site. The proposed development requires a total of ten (10) parking spaces, which accounts for the office use, residential use, visitor parking and barrier free parking. That said, the applicant is proposing a total of seven (7) parking spaces, which in the opinion of Staff is sufficient for the proposed development. The current parking supply will provide for at least one space per residential unit, which is now the standard for any residential development within a downtown core. The proposed office on the ground floor is to function as a live-work unit, only open to the private residents of the building, therefore, not creating any additional public traffic onsite. When taking that into consideration that there are areas currently within the Aurora Promenade that requires only one space per unit, inclusive of visitor parking spaces, the proposed seven (7) parking spaces is sufficient to accommodate the residential development. Residential projects within a downtown core are focused on transit-orientated development and to prioritize intensification within the Secondary Plan area as the Town’s primary location for growth and density, reinforcing the importance of the Aurora GO Station as a Major Transit Station area. Furthermore, when the applicant originally presented the minor variance application, a variance pertaining to the minimum distance separation for the barrier free parking space was also required. However, after further consultation with Staff and design changes to the building, the applicant was able to accommodate the barrier free parking space and its appropriate standard to eliminate the need for the additional variance. Given this change, the minor variance application only requires two variances versus the original three. The proposed seven (7) parking spaces meets the general intent of the Zoning By-law and is sufficient for the future development of the subject property. Page 24 of 40 December 12, 2024 6 of 11 Report No. MV-2024-28 c) The proposed variance is considered desirable for the appropriate development of the land As discussed above, Staff are satisfied the proposal adequately responds to the newly adopted Town of Aurora Official Plan 2024, and the criteria for new development within the Aurora Promenade and Major Transit Station Area. The proposed development will also provide critical new and attainable housing opportunities for the local community. The proposed infill residential development enhances the urban design of the neighbourhood by providing the wise use and management of land within the Aurora Promenade. In addition, the proposed development will promote a truly mixed residential community that houses people of different ages, backgrounds, lifestyles and economic status. The Promenade is envisioned to function as a vibrant, mixed-use, pedestrian oriented community with a range and mix of housing options and densities and access to higher order transit. Primarily though, the need for new, diverse, and attainable housing is paramount and the ability for the proposed development to add rental housing units to the Aurora Promenade is of benefit to current and future generations in addressing various housing needs. The proposed intensification of an underutilized lot aligns with the direction of the Province under Bill 23. The increase in building height and reduced parking standards will not negatively impact the surrounding area but enhance the overall function of the subject property and align with the vision of development with the Aurora Promenade. Lake Simcoe Region Conservation Authority has reviewed the application and confirmed that based on the information submitted as part of this minor variance application, the proposal is located outside of the flood hazard and is therefore consistent with 3.1 of the Provincial Policy Statement (PPS). The appropriate condition s of approval have been implemented, requiring the applicant to obtain a permit from the LSRCA prior to development or site alteration. Overall, it is the opinion of Staff that the proposed variances are considered desirable for the appropriate development of the land. d) The proposed variance is considered minor in nature In the opinion of staff, the requested variances are considered to be minor in nature and are not expected to have any significant adverse effects on the subject property, neighbouring properties, or the overall streetscape. The proposed development is designed to implement the building height policies of Official Plan and the Aurora Promenade and Major Transit Station Secondary Plan Area. The proposed increase in maximum height from a numerical value is double but does not accurately depict what Page 25 of 40 December 12, 2024 7 of 11 Report No. MV-2024-28 can be done on the property as of right. Furthermore, the reduction in parking can adequately serve the proposed residential development without negatively impacting surrounding properties. The proposal introduces new and attainable rental housing opportunities in a manner that still respects the overall neighbourhood character and scale. The appropriate conditions of approval have also been developed, including for the need to obtain a Road Occupancy Permit, and to ensure any tree removals are evaluated through an evaluation report completed by a certified professional. The Town’s Engineering Department has also reviewed the updated site plan and are satisfied with the daylighting triangle being provided at the corner of Tyler and Temperance Street. The are no comments as it pertains to the proposed development. Overall, it is the opinion of Staff that the proposed variances are minor in nature. Additional Comments The minor variance application was circulated to Town Department/Divisions and to external agencies for review and comment. The following comments were provided: Department or Agency Comments Building Division Preliminary Zoning Review completed. No objection. Engineering Division No objection. Operational Services (Parks) No objection. Operations (Public Works) No objection. Central York Fire Services No objection. York Region No objection. LSRCA No objection. Alectra No objection. Page 26 of 40 December 12, 2024 8 of 11 Report No. MV-2024-28 Public Correspondence At the time of writing this report, three written submissions in opposition were received. If additional written submissions are received after the writing of this report, the Secretary-Treasurer will provide the submission(s) to Committee members at the meeting. Conclusion Planning staff have reviewed the application regarding Section 45 (1) of the Planning Act, R.S.O, 1990, c.P.13, as amended, and believe that the requested variance meets the four tests of the Planning Act for granting minor variances. Staff recommend approval of the requested variance subject to the condition outlined in Appendix ‘A. Attachments Appendix ‘A’ – Recommended Conditions of Approval Appendix ‘B’ – Site Plan & Elevations Appendix ‘C’ – Floor Plans & Elevations Page 27 of 40 December 12, 2024 9 of 11 Report No. MV-2024-28 Appendix ‘A’ – Conditions of Approval Planning and Development Services: 1. That the variance only applies to the subject property in conformity with the plans attached as ‘Appendix B’ to this Staff Report, to the satisfaction of the Director of Planning and Development Services or designate. 2. That the owner obtain Site Plan Exemption approval as it relates to the office component of the development. 3. That the owner obtains necessary clearance from Town of Aurora Council to remove (delist) the property from the Town's Heritage Register. Consultation will also be required to occur with the Town's Heritage Advisory Committee (HAC), and the submission of a Cultural Heritage Evaluation Report will be required demonstrating support. Operational Services – Parks Division: 4. That the owner shall be required to provide an Evaluation Report prepared by a Certified Arborist or Professional Registered Forester outlining all aspects of the impacts that this proposal will have on existing trees. The report shall include the following: a. An assessment of existing trees (5cm trunk diameter and greater) by size, species and condition including trees on adjacent properties whose structure or root zone may be impacted by construction. b. Identification of all tree injuries and tree removals, if any. c. Identification of all tree protection measures including recommendations on the mitigation of negative effects to trees during and post construction, including applicable maintenance requirements. d. Provision of monitoring of the site work through a series of site visits by the Arborist/Forester to ensure protection/preservation measures remain in compliance throughout the duration of the project. Monitoring shall occur i) at commencement of work to certify all tree protection measures are in place, ii) during site work to confirm protection measures are in place and to oversee arboriculture works as required, and iii) post construction Page 28 of 40 December 12, 2024 10 of 11 Report No. MV-2024-28 assessment. Each site visit is to be documented, and any resulting action items required by the Arborist /Forester shall be implemented and confirmed on site forthwith by the Arborist /Forester following each visit. e. A monetary evaluation in accordance with the Town’s Tree Compensation Policies for all trees designated to be removed. 5. The Owner shall be required to provide a tree compensation and a replanting plan in accordance with the Town of Aurora Tree Compensation Policies to the satisfaction of the Director of Operational Services as compensation for trees removed to facilitate construction. Compensation planting shall be completed prior to release of the financial securities. 6. The owner shall agree to comply with the Aurora Tree Permit By-law # 5850 -16 prior to the removal of any trees on the property. 7. The owner shall be required to provide financial securities based on the total value of the Tree Compensation evaluation and all Arboriculture works as defined by the Town and the Owner’s Arborist/ Forester, to the satisfaction of the Director of Operational Services. 8. All the above shall be included as terms and conditions in a Letter of Undertaking with the Town of Aurora to guarantee compliance with the Conditions of Approval and all related site works. Operational Services – Public Works: 9. That the Owner obtain a Road Occupancy Permit through Public Works. 10. That the Owner be required to CCTV the existing sanitary to see if it can be used for this proposed development. The developer will also be required to confirm the size of the water service. Lake Simcoe Region Conservation Authority: 11. That the Applicant/Owner shall pay the LSRCA Plan Review Fee in accordance with the approved LSRCA Fee Schedule. The applicable fee for Minor Variance (Minor – planner review only) is $536.00. 12. That the Applicant/Owner successfully obtain a permit from the LSRCA prior to development or site alteration. Page 29 of 40 December 12, 2024 11 of 11 Report No. MV-2024-28 York Region: 13. A Section 59 applies at the minor variance stage and needs to be completed prior to approval. Please have the applicant submit Section 59 - Planning Application Form. 14. Prior to final approval of the application, the Town of Aurora shall confirm that adequate water supply and sewage capacity has been allocated for the proposed dwellings. Page 30 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNEXISTING GROUND FLOOR PLANA-01PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 31 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED SECOND/THIRD FLOORA-02PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 JULY 27, 2024Page 32 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED FORTH GROUND FLOORA-03PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.BRASSFAUCETMARGAUXK-16232-4 GASFIREPLACE JULY 27, 2024Page 33 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED MEZZANINE FLOORA-04PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 JULY 27, 2024Page 34 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED ROOF TOP PATIOA-05PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 35 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNNORTH (FRONT) ELEVATIONA-06PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 36 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNWEST (SIDE) ELEVATIONA-07PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 37 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNEAST (SIDE) ELEVATIONA-08PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 38 of 40 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNSOUTH (REAR) ELEVATIONA-09PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 39 of 40 31.76 12.66 1.27BOREHOLE LOCATIONUSFUNDERSIDE FOOTING ELEVATIONTFWFBSFFLGHSW1 0 0 . 0 0100.00HWENGINEERED FILL LOTDOWNSPOUT LOCATIONTELECOM. JUNCTION BOXFINISHED FLOOR ELEVATIONTOP OF FOUNDATION WALLFIN. BASEMENT FLOOR SLABGAS METERPROPOSED BERMSWALE DIRECTIONHYDRO METERSANITARY MANHOLEVALVE AND CHAMBERAIR-CONDITIONING UNIT PROPOSED SWALE GRADEEXISTING GRADEPROPOSED GRADESTORM MANHOLESTREET LIGHTCABLE TV PEDESTALCOMMUNITY MAILBOXENTRANCE DOOR LOCATIONGARAGE DOOR LOCATIONBELL PEDESTALHYDRANTTRANSFORMERSTORM CONNECTIONHYDRO CONNECTIONDOUBLE CATCH BASINWATER CONNECTIONSANITARY CONNECTIONCATCH BASINMAILLEGENDBH 1AA'SLOPE SECTIONRRECYCLING BINGGARBAGE BINDISTANCES SHOWN ON THIS PLAN AREIN METRES AND CAN BE CONVERTEDTO FEET BY DIVIDING BY 0.3048.METRICSITE STATS(m)EASTWEST20SPATIAL SEPARATION-CONSTRUCTION OF EXTERIOR WALLSWALLAREAOF EBFL.D.L/HORH/LPERMITTEDMAX.% OFOPENINGSPROPOSED% OFOPENINGSFRR(HOURS)LISTED DESIGNOR DESCRIPTIONCOMB.CONSTCOMB.CONSTR./NON-COMB.CLADDINGONTARIO BUILDING CODE DATA MATRIXITEMOBC REFERENCE PART 3PART 9 PART 11 NEW ADDITION ALTERATION CHANGE OF USEPROJECT DESCRIPTION:12345678910111213141516171819MAJOR OCCUPANCY(S)BUILDING AREA (m )GROSS AREA (m )NUMBER OF STOREYS ABOVE GRADE___ BELOW GRADE___HEIGHT OF BUILDING (m)NUMBER OF STREETS/ACCESS ROUTESBUILDING CLASSIFICATIONSPRINKLER SYSTEM PROPOSED ENTIRE BUILDING BASEMENT ONLY IN LIEU OF ROOF RATING NOT REQUIRED NO YESSTANDPIPE REQUIREDFIRE ALARM REQUIREDWATER SERVICE/ SUPPLY IS ADEQUATEHIGH BUILDINGPERMITTED CONSTRUCTIONACTUAL CONSTRUCTION COMBUSTIBLE COMBUSTIBLE NON-COMBUSTIBLE NON-COMBUSTIBLEBOTHBOTHMEZZANINE(S) AREA m DESIGN OF BUILDING m /PERSONOCCUPANT LOAD BASED ONBASEMENT:1st FLOOR2nd/3rd FLOOR4th FLOOROCCUPANCY________ LOAD________ PERSONSOCCUPANCY________ LOAD________ PERSONSOCCUPANCY________ LOAD________ PERSONSOCCUPANCY________ LOAD________ PERSONS YES YES NO NOLISTED DESIGN NO. ORDESCRIPTION (SG-2)HORIZONTAL ASSEMBLIESFRR (HOURS)REQUIRED FIRERESISTANCERATING (FRR)FLOORS ______HOURSROOFS ______HOURSMEZZANINE______HOURSFRR OF SUPPORTING MEMBERSBARRIER-FREE DESIGNHAZARDOUS SUBSTANCESFLOORS ______HOURSROOFS ______HOURSMEZZANINE______HOURS YES YES YES NO NO NOCOMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey, structural,mechanical, electrical, etc. engineering information shown on the drawing. Refer to theappropriate engineering drawings before proceeding with work.Contractor shall check all dimensions on the work and report any discrepancy to theArchitectural Technologist before proceeding. Construction must conform to all applicableCodes and Requirement of Authorities having Jurisdiction.All drawings, specifications and related documents are the copyright property of Peter DelGrosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNSITE PLANSP-01PROPOSED 4 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 24/241:200PDG00-001.DEC. 9/23ISSUED FOR REVIEW2.SEPT. 16/24REV. BARRIER-FREE PARKING3.OCT. 1/24REDUCED FRONT YOARD SETBACK4.5.6.7.8.31.76 P15.30 P2P311.042.705.300.263.65 P4P5P6P71.50 6.00 6.00 8. 9 8 25.76 1.480.501.803.03 13.03 7.07 7.46Page 40 of 40