Loading...
Agenda - Committee of Adjustment - 20241010Town of Aurora Committee of Adjustment Meeting Agenda Date:Thursday, October 10, 2024 Time:7 p.m. Location:Video Conference Meetings are available to the public via live stream on the Town’s YouTube channel. To participate electronically, please visit aurora.ca/participation. Pages 1.Call to Order 2.Land Acknowledgement 3.Approval of the Agenda That the Agenda as circulated by the Secretary-Treasurer be approved. 4.Declarations of Pecuniary Interest and General Nature Thereof 5.Receipt of the Minutes 5.1 Committee of Adjustment Meeting Minutes of September 12, 2024, Meeting Number 24-09 1 That the Committee of Adjustment Minutes from Meeting Number 24-09 be adopted as circulated. 6.Presentation of Applications 6.1 MV-2024-24 - Vata Holding Ltd. - 5 Vata Court 8 6.2 MV-2024-25 - 2209640 Ontario Ltd. - 95 Dunning Ave 16 6.3 MV-2024-27 -Inamdar - 69 Kennedy St. E 32 6.4 MV-2024-28 - Risk - 15 Tyler St 43 7.New Business 8.Adjournment 1 Town of Aurora Committee of Adjustment Meeting Minutes Date: Time: Location: Thursday, September 12, 2024 7 p.m. Video Conference Committee Members: David Mhango (Chair) Chris Polsinelli Michael Visconti Julian Yang Members Absent: Jane Stevenson (Vice Chair) Other Attendees: Peter Fan, Secretary-Treasurer, Committee of Adjustment Antonio Greco, Senior Planner _____________________________________________________________________ 1. Call to Order That the meeting be called to order at 7:04 PM. 2. Land Acknowledgement The Town of Aurora acknowledges that the Anishinaabe (A-nishshaw-na-bee) lands on which we live, and work are the traditional and treaty territory of the Chippewas of Georgina Island, as well as many other Nations whose presence here continues to this day. As the closest First Nation community to Aurora, we recognize the special relationship the Chippewas have with the lands and waters of this territory. They are the water protectors and environmental stewards of these lands, and as a municipality we join them in these responsibilities. Page 1 of 62 2 We further acknowledge that Aurora is part of the treaty lands of the Mississaugas and Chippewas, recognized through Treaty #13 as well as the Williams Treaties of 1923. A shared understanding of the rich cultural heritage that has existed for centuries, and how our collective past brought us to where we are today, will help us walk together into a better future. 3. Approval of the Agenda Moved by Julian Yang Seconded by Michael Visconti That the Agenda as circulated by the Secretary-Treasurer be approved. Carried 4. Declarations of Pecuniary Interest and General Nature Thereof None. 5. Receipt of the Minutes 5.1 Committee of Adjustment Meeting Minutes of August 8, 2024, Meeting Number 24-08 Moved by Michael Visconti Seconded by Julian Yang That the Committee of Adjustment Minutes from Meeting Number 24-08 be adopted as printed and circulated. Carried 6. Presentation of Applications 6.1 MV-2024-01 - Liu - 2007 Vandorf Sideroad Planning Staff are requesting a deferral of the above noted minor variance application for 2007 Vandorf Sideroad (MV-2024-01). Additional time is needed for the Ontario Ministry of Transportation (MTO) to review the subject application. The MTO has identified that a portion of the proposed development is within the required setback from the MTO Page 2 of 62 3 property line and requires that the proposal be revised to ensure that no development is within the setback. Moved by Julian Yang Seconded by Chris Polsinelli That the Minor Variance Application MV-2024-01 be DEFERRED Carried 6.2 MV-2024-20 - Irvine - 313 Ridge Rd The applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the construction of a one-storey addition to the easterly side of the existing dwelling, a front covered porch, an expansion to the existing outdoor rear deck and a one storey workshop/garage addition to the westerly side of the existing dwelling. The following relief is being requested: 1) Section 14.1 of the Zoning By-law states no person shall use the land, including expanding, enlarging or otherwise altering an existing use, building or structure, for any use other than a use legally existing as of November 15, 2001, without amendment to, or relief from the Zoning By-law. a) The applicant is proposing to construct a one-storey addition, covered porch and deck that did not exist prior to November 15, 2001, thereby requiring a minor variance. 2) Section 14.1.b(i) of the Zoning By-law requires a minimum exterior side yard of 15.0 metres. a) The applicant is proposing a one-storey addition and deck, which is 12.6 metres to the exterior side property line, thereby requiring a variance of 2.4 metres. 3) Section 14.1.b(i) of the Zoning By-law requires a minimum front yard of 15.0 metres. Page 3 of 62 4 a) The applicant is proposing a one-storey garage addition, which is 13.8 metres to the front property line, thereby requiring a variance of 1.2 metres. The Chair invited the Applicant or Owner to address the Committee. In attendance was the agent Kristen Aleong and Katie Rose. The agent provided a brief introduction and presentation to their application. The Chair invited members of the public to provide comments. There were no public delegates in attendance for this application. The Committee requested clarification on whether the agent or applicant agrees with the conditions outlined in the staff report. Additionally, the Committee inquired if the proposed addition would necessitate the installation of a new septic system. Moved by Michael Visconti Seconded by Julian Yang That the Minor Variance application MV-2024-20 be APPROVED Carried 6.3 MV-2023-44 - The Biglieri Group - 100 Goulding Avenue The applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the development of a 3-storey industrial/office building with accessory restaurant use. The proposed site plan is attached as Appendix ‘B’ to this report for reference. The following relief is being requested: 1. Section 10.2 of the Zoning By-law 6000-17 states that the maximum building height be 13.5 metres. The applicant is proposing 17.3 metres, thereby requiring a variance of 3.8 metres. 2. Section 24.338.2.1 of the Zoning By-law 6000-17 states that the maximum Floor Area Ratio for Office Use to be 17%. The applicant is proposing 35%, thereby requiring a variance of 18%. The Chair invited the Applicant or Owner to address the Committee. In attendance was the agent Shilpi Saraf-Uiterlinden. The agent provided a brief introduction and presentation to their application. Page 4 of 62 5 The Chair invited members of the public to provide comments. There were no public delegates in attendance for this application. The Committee asked Town staff to explain the rationale behind the 17% Floor Area Ratio specified in the Zoning By-law. They also inquired about the number of parking spaces provided both above and below ground, as well as the type of restaurant planned for the proposed space. Moved by Chris Polsinelli Seconded by Julian Yang That the Minor Variance Application MV-2023-44 be APPROVED Carried 6.4 C-2024-02 - Cornerstone Growth Investment Corp. - 31 Kennedy St. W The purpose of the proposed consent application is to sever the subject lands with frontages along Kennedy Street West as follows (see Appendix ‘B’): 1) Proposed Severed Lands: a) Part 1 of the Draft Plan of Severance (western portion) b) A lot area of 432.7 m2 (4650 ft2) and a lot frontage of 15.26 m (50.1 ft) 2) Proposed Retained Lands: a) Part 2 of the Draft Plan of Severance (eastern portion) b) A lot area of 446.7 m2 (4808.2 ft2) and a lot frontage of 15.25 m The Chair invited the Applicant or Owner to address the Committee. In attendance was the owner Meaghan Li. The owner provided a brief introduction and presentation to their application. The Chair invited members of the public to share their comments. One public delegate, David Fletcher, was present for this application. David spoke in opposition to the proposal, citing concerns about the neighborhood's overall appearance, as well as its historic and heritage elements. The Committee asked staff how stormwater and runoff would be managed if the application were approved. They also noted that, under Bill Page 5 of 62 6 23, the applicant could potentially proceed with their proposed development without the need for consent. The Committee sought clarification on why the applicant is currently seeking a severance. The Committee also inquired about the laneway, specifically whether the proposed development would affect access and municipal services. They also inquired to the applicant in whether she would consider the plans provided by one of the letters of opposition for a development of 16 Townhouses. Moved by Chris Polsinelli Seconded by Michael Visconti That the Consent Application C-2024-02 be APPROVED Carried 6.5 MV-2024-17, MV-2024-18 - Cornerstone Growth Investment Corp - 31 Kennedy St. W The applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the creation of one (1) new residential lot through Consent Application C- 2024-02. The following relief is being requested: 1) MV-2024-17 – Part 1 – Proposed Severed Lot (western portion): a) Section 7.2 of the Zoning By-law requires a minimum lot area of 460.0 m2. The applicant is proposing a lot area of 432.7 m2. 2) MV-2024-18 – Part 2 – Proposed Retained Lot (eastern portion): a) Section 7.2 of the Zoning By-law requires a minimum lot area of 460.0 m2. The applicant is proposing a lot area of 446.7 m2. b) Section 24.497.3.2 of the Zoning By-law requires a minimum interior side yard of 1.5 m. The existing one-storey detached dwelling is 1.2 m to the proposed interior side property line. The Chair invited members of the public to share their comments. One public delegate, David Fletcher, was present for this application. David spoke in opposition to the proposal, citing concerns about the neighborhood's overall appearance, as well as its historic and heritage elements. Page 6 of 62 7 The Committee asked staff how stormwater and runoff would be managed if the application were approved. They also noted that, under Bill 23, the applicant could potentially proceed with their proposed development without the need for consent. The Committee sought clarification on why the applicant is currently seeking a severance. The Committee also inquired about the laneway, specifically whether the proposed development would affect access and municipal services. They also inquired to the applicant in whether she would consider the plans provided by one of the letters of opposition for a development of 16 Townhouses. Moved by Chris Polsinelli Seconded by Michael Visconti That the Minor Variance Application MV-2024-17 be APPROVED Carried Moved by Michael Visconti Seconded by Chris Polsinelli That the Minor Variance Application MV-2024-18 be APPROVED Carried 7. New Business None. 8. Adjournment Moved by Julian Yang That the meeting be adjourned at 9:14PM. Carried Page 7 of 62 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 4 -24 _______________________________________________________________________________________ Subject: Minor Variance Application Vata Holding Limited 5 Vata Court PLAN 10328 LOT 31 File: MV-2024-24 Prepared by: Felix Chau, Planner Department: Planning and Development Services Date: October 10, 2024 _______________________________________________________________________________________ Application The owner is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate overnight accommodation within the “Pet Services” permitted use. The following relief is being requested: a) Section 3 of Zoning By-law 6000-17 under the definition of “Pet Services” does not allow for overnight accommodation for animals. The applicant is proposing overnight accommodations for animals. Background Subject Property and Area Context The subject property is located east of Edward Street and south of Engelhard Drive, on the east end of the Vata Court cul-de-sac. The subject property has an area of approximately 4,046.9 m2 (43,560 ft2) and a frontage of roughly 24 m (79 ft) on Vata Court. The subject property contains an industrial building. Proposal The applicant is requesting a minor variance application to permit overnight accommodation within the “Pet Services” permitted use, specifically for unit nine (9) of the industrial building. The existing tenant, “C & D Pet Hotel Inc.”, currently provides Page 8 of 62 October 10, 2024 2 of 6 Report No. MV-2024-24 services including pet grooming and daycare and is looking to add overnight pet boarding services to their operation. No physical exterior changes to the existing industrial building or subject property are proposed in this application. Official Plan The subject property is designated “General Industrial” by the Town of Aurora Official Plan. This designation is intended to ensure long-term protection and continued evolution of existing industrial areas in the Town. A broad range of employment opportunities as well as ancillary service and small-scale retail uses are permissible. Zoning The subject property is zoned “E2 – General Employment Zone” under Zoning By-law 6000-17, as amended. This zoning permits pet services and various employment-related uses. Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town of Aurora’s Building Division. The PZR identified the required variance, and no other non-compliance was identified. Applicant’s stated reason(s) for not complying with the Zoning By-law As stated on the application form, the applicant is looking to add overnight pet boarding services to their existing business. The applicant indicates that without overnight pet boarding services, the business has suffered substantial losses since leasing the unit in October 2022, as the original business plan and proforma included revenues from overnight pet boarding. Planning Comments Planning Staff have evaluated Minor Variance Application MV-2024-24 pursuant to the prescribed tests as set out in Section 45 (1) of the Planning Act, as follows: a) The proposed variance meets the general intent of the Official Plan The subject property is designated “General Industrial” by the Town of Aurora Official Plan. This designation is intended to ensure the long-term protection and continued evolution of existing, older industrial areas. Within this designation, a broad range of Page 9 of 62 October 10, 2024 3 of 6 Report No. MV-2024-24 employment opportunities as well as ancillary service and small-scale retail uses are permissible. The proposed variance which requests to add overnight accommodations to a “Pet Services” use conforms to the Official Plan and provides for a service commercial use that is permitted under the General Industrial designation. Additionally, the proposed variance will contribute to the Town’s economic growth and generate local job opportunities. Planning staff are of the opinion that the requested minor variance maintains the general intent and purpose of the Official Plan. b) The proposed variance meets the general intent of the Zoning By-law The subject lands are zoned “E2 – General Employment” by Zoning By-law 6000-17, as amended, which permits a wide variety of uses such as pet services, industrial uses, offices, food processing establishments, fitness centres, and repair shops. The “Pet Services” use, as defined by Zoning By-law 6000-17, means premises used for the aesthetic care, animal daycare or training facility of animals or birds intended for the use as domestic household pets and shall be placed within a wholly enclosed building. Animal daycare will not include overnight accommodation. As previously mentioned, the existing tenant, “C & D Pet Hotel Inc.”, currently provides services including dog grooming and daycare in Unit 9 of the industrial building. The tenant is proposing to add overnight boarding services to their business operation. Currently, there is a total of 12 partition for dogs which will remain at the business. Furthermore, the maximum number of dogs that can be accommodated overnight is 12. There are no physical exterior changes to the existing industrial building or subject property. The proposed overnight accommodation use will be accessory to the existing primary Pet Services use. The proposed use relates to caring for domestic animals, which is consistent with other uses currently permitted in the General Employment (E2) Zone. A variance to permit overnight accommodation at the subject property is in keeping within the range of permitted uses in the E2 Zone, and it is an essential element of subject business which has been foregone due the zoning requirements. Staff are of the opinion that the subject variance maintains the general intent and purpose of the Zoning By-law. c) The proposed variance is considered desirable for the appropriate development of the land Page 10 of 62 October 10, 2024 4 of 6 Report No. MV-2024-24 The subject property is located in an industrial area within the Town that predominantly contains employment, industrial, and manufacturing uses. The industrial building currently contains four (4) tenants: a dance studio, a meat packing facility, a sign manufacture, and the subject pet services shop. No other business within the building operates overnight. Furthermore, the subject business is located within an end unit of the industrial building, which mitigates potential noise impacts. The proposed variance also demonstrates the vision and fundamental principles outlined in the Official Plan through the “Advancing the Economy” principle. This speaks to encouraging a competitive business environment and ultimately advancing and sustaining Aurora’s long-term economic prosperity. The business currently employs three employees and with the addition of the overnight accommodation function, the applicant has indicated that an additional one to two night shift staff will be hired. The proposed minor variance application allows for the enhancement of a local business and the ability to live, work, and play within the Town of Aurora. Staff believe that the variance is considered desirable for the appropriate development of the land. d) The proposed variance is considered minor in nature The request to permit overnight accommodation for the “Pet Services” permitted use is minor in nature and will not negatively impact the industrial building or su rrounding area. The subject variance to permit overnight accommodation use inside the premises is considered to maintain the integrity of the Official Plan and Zoning Bylaw. It is not considered to impact the surrounding neighbourhood. Furthermore, no physical changes to the building or parking are proposed or required. Given the types of uses immediately surrounding the proposed location of the business, their hours of operation, and the fact that no forms of residential development exist within a 200 m radius of the subject property, the proposed use of the subject property will not detract from the overall site and surrounding area’s employment/industrial character. Overall, staff considers the proposed variances minor in nature Page 11 of 62 October 10, 2024 5 of 6 Report No. MV-2024-24 Additional Comments The minor variance application was circulated to Town Department/Divisions and to external agencies for review and comment. The following comments were provided: Department or Agency Comments Building Division Preliminary Zoning Review completed. No objection. Engineering Division No objection. Operational Services (Parks) No objection. Operations (Public Works) No objection. Central York Fire Services No objection. York Region No objection. LSRCA No objection. Public Correspondence Written submissions were not received at the time of writing of this report. Should written submissions be received after the writing of this report, the Secretary Treasurer will provide the submission(s) to Committee members at the meeting. Conclusion Planning Staff have reviewed the application with respect to Section 45 (1) of the Planning Act, R.S.O., 1990, c.P.13, as amended, and believe that the requested variance meets the four tests of the Planning Act for granting minor variances. Staff recommend approval of the requested variance subject to the condition outlined in Appendix ‘A’. Attachments Appendix ‘A’ – Recommended Conditions of Approval Appendix ‘B’ – Site Plan Appendix ‘C’ – Floor Plan Page 12 of 62 October 10, 2024 6 of 6 Report No. MV-2024-24 Appendix ‘A’ – Conditions of Approval Planning and Development Services: 1. That the variance only applies to the subject property in conformity with the plans attached as ‘Appendix B’ to this Staff Report, to the satisfaction of the Director of Planning and Development Services or designate. Page 13 of 62 Page 14 of 62 Page 15 of 62 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 4 -25 _______________________________________________________________________________________ Subject: Minor Variance Application 95 Dunning Avenue Design Plan Services Inc. (c/o David Ingelman) CON 1 PT LOT 77 PLAN 488 PT BLK A & B PLAN 10328 LOT 36 RP 65R7942 PARTS 3 5 AND 6 RP 65R17425 PART 1 RP 65R1318 PT PART 1 File: MV-2024-25 Prepared by: Katherine Gatzos, Planner Department: Planning and Development Services Date: October 10, 2024 _______________________________________________________________________________________ Application The owner/applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law No. 6000-17, as amended, to facilitate the use of a Medical Marihuana Production Facility. Based on the information provided to the Town, the following relief is being requested: a) Section 10.1 of the Zoning By-law No. 6000-17 permits a Medical Marihuana Production Use only in a Business Park (E-BP) zoning district.  The applicant is proposing a Medical Marijuana Production Use in a General Employment (E2) zoning district. Background Subject Property and Area Context The subject property, municipally known as 95 Dunning Avenue, is located on the east side of Edward Street, north of Engelhard Drive, and abuts the Metrolinx rail corridor to the east. The subject property has a total area of approximately 2.68 hectares (6.63 acres) and has frontage on three (3) streets, Dunning Avenue, Edward Street, and Engelhard Drive. Page 16 of 62 October 10, 2024 2 of 7 Report No. MV-2024-25 The subject property presently contains an existing industrial building, with a total gross floor area of 16940 sqm. Only the north unit of the building (6211 sqm) is proposed to be used as a Medical Marihuana Production Facility. The south portion of the building is occupied by a different tenant and is an automotive parts storage facility. North: Dunning Avenue, Industrial uses, Sheppard’s Bush Soccer Field South: Engelhard Drive, The Lighthouse Learning and Development Centre, Industrial uses East: Metrolinx GO Transit Corridor, Kids Supergym Gymnastics Studio, EarlyON Child & Family Centres Aurora, Wood Wellness Centre, Industrial uses West: Edward Street, Residential uses, Jack Wood Park, The Gathering Place Church, Dr. G. W. Williams Secondary School, Industrial uses Proposal The applicant is requesting the subject variance to facilitate a “Medical Marihuana Production Facility” use on the subject property, zoned General Employment (E2). As indicated above, only the north unit of the existing building is proposed to be used as a Medical Marihuana Production Facility. The applicant has indicated that the north portion of the existing building has been used as a Medical Marihuana Production Facility for four (4) years. The applicant stated that the proposed Medical Marihuana Production Facility will not include the export or sale of the medical Marihuana produced onsite, and that medical Marihuana produced onsite would be used for personal, medicinal use. Project History In July 2020, the Town of Aurora received a complaint regarding the illegal operation of a Medical Marihuana Production Facility at 95 Dunning Avenue. In October 2022, the Building Division laid charges for the non-permitted use of the subject property as a Medical Marihuana Production Facility. Since 2022, there have been numerous court appearances, with each appearance being adjourned to provide the owner the opportunity to file a planning application to legalize the use. At a recent court appearance on July 18, 2024, the Town requested that the matter be set for trial as the Town had not yet received any planning applications for the subject property and the illegal use continued. Instead, the court scheduled a judicial pre-trial hearing for September 6, 2024. Unfortunately, the court was delayed with other matters on September 6 and therefore, could not proceed with the hearing. The Town continued to Page 17 of 62 October 10, 2024 3 of 7 Report No. MV-2024-25 request a trial date. In response, the courts adjourned the Judicial Pre-trial hearing to October 22, 2024, and set a trial date for November 17, 2024. In the meantime, a Pre-Consultation meeting was held for the subject proposal on February 22, 2024. At this time, Town Planning Staff indicated they would not support the introduction of a Medical Marihuana Production Facility on the subject property, and encouraged the applicant to explore alternative locations that would support th is use. However, the applicant maintained their intent to pursue recognition of the use on the subject property. In response, Town Planning Staff indicated to the applicant that due to the nature of the proposed use, a Major Zoning By-law Amendment and Site Plan Amendment would be the most applicable applications to address this and maintained that the Town would not be supportive of introducing a Medical Marihuana Production Facility on the subject property. Against Staff’s opinion, the applicant has decided to move forward with their request to permit the Medical Marihuana Production Facility use on the subject property and has chosen to address this non-compliance with a Minor Variance application. Official Plan The subject property is designated “General Industrial” in the Town of Aurora Official Plan (2024). The General Industrial designation applies to existing, older, industrial areas in the Town, including areas along Industrial Parkway North and South. This designation includes industrial and manufacturing uses, warehouse facilities and distribution centres, and the storage of goods and materials as permitted uses, subject to additional provisions. Zoning The subject property is zoned “General Employment” (E2) in the Town of Aurora Zoning By-law 6000-17, as amended. Marihuana Production Facilities are not permitted in the E2 zone. Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town of Aurora’s Building Division. The PZR identified the required variance, and no other non-compliance was identified. Applicant’s stated reason(s) for not complying with the Zoning By-law As stated on the application form, “The proposal is to legalize the medical Marihuana production use, for the personal use of the medical Marihuana license holders, within the Page 18 of 62 October 10, 2024 4 of 7 Report No. MV-2024-25 north portion of the existing building. The proposed use is not permitted within the existing “General Employment” zone and thus requires relief from the By-law. Planning Comments Planning Staff have evaluated Minor Variance Application MV-2024-25 pursuant to the prescribed tests as set out in Section 45(1) of the Planning Act, R.S.O, 1990, c.P.13, as amended (the “Planning Act”) as follows: a) The proposed variance does not meet the general intent of the Official Plan The General Industrial designation applies to historical industrial areas surrounding Industrial Parkway North and South which exist in close proximity to residential uses west of Edward Street. The intent of the General Industrial designation of the Town’s Official Plan is to permit a variety of industrial uses including manufacturing and warehousing, however, this must be done so in a manner that does not negatively impact surrounding land uses. The proposed Medical Marihuana Production Facility is clas sified as a manufacturing facility and as such can be considered a permitted use within the General Industrial designation. Although a permitted use within the General Industrial designation, Section 10.7.3(e) of the Official Plan states “Permitted uses sh all not emit noticeable or noxious … air emissions which negatively impact adjacent land uses”. Staff have concerns regarding the potential cannabis odor emitting from the facility, which would negatively impact surrounding sensitive land uses, including established residential areas, community spaces including Jack Wood Park and the Gathering Place, and Dr. G. W. Williams Secondary School, just west of Edward Street (a local road). The surrounding local area also includes businesses providing services to children and vulnerable persons which may be negatively impacted due to exposure to cannabis odor, including the Lighthouse Learning and Development Centre, Out of the Wood Wellness Centre, EarlyON Child & Family Centres Aurora and Kids Supergym Gymnastics Studio. Staff are of the opinion that the Medical Marihuana Production Facility has the pote ntial to emit odors and emissions that negatively impact adjacent land uses, and is therefore considered incompatible with surrounding uses, particularly sensitive land uses including residential zones, places of worship, childcare facilities and schools, and other community gathering spaces. Page 19 of 62 October 10, 2024 5 of 7 Report No. MV-2024-25 As such, staff are of the opinion that the proposed variance does not meet the general intent of the Official Plan. b) The proposed variance does not meet the general intent of the Zoning By-law The subject property is zoned “General Employment” (E2) by the Town of Aurora Zoning By-law No. 6000-17, as amended. Section 10.1 of the Zoning By-law does not permit the “Medical Marihuana Production Facility” use in the General Employment Zone. On May 27, 2014, Town of Aurora Council passed Interim Control By-law (ICBL) No. 5626- 14, to prohibit the use of the Town’s Employment Lands for Medical Marihuana Production. On May 26, 2015, following consultation with other municipalities and industry representatives, Council enacted By-law No. 5732-15, which amends the Zoning By-law, to restrict the use of Medical Marihuana Production to lands zoned Business Park (E-BP). The intent of By-law No. 5732-15 is to balance the economic interests associated with cannabis businesses, with the well-being of Town residents. Lands zoned Business Park are typically located along the Highway 404 corridor, where there are few residential zones present, and therefore less opportunity for negative impacts related to noise and air emissions. The intent in regulating the location of Medical Marijuana Production Facilities is to limit exposure and impacts typically attributed to noxious, nuisance, and noticeable odors and/or emissions from said facilities on the surrounding area, particularly properties that consist of sensitive land uses. As indicated previously, the subject property is surrounded by residential areas, community spaces, and schools. Therefore, staff consider permitting a Medical Marijuana Production Facility on the subject property to be inappropriate due to the surrounding neighbourhood context, and incompatible with the intent of the Zoning By- law regulations. Through the implementation of By-law Nos. 5626-14 and 5732-15, the Town has reinforced its stance on this matter, ensuring that Medical Marihuana Production Facilities are not to be permitted within the General Employment zone. As such, staff are of the opinion that permitting a Medical Marihuana Production Facility on the subject property would be in violation of the Town’s Zoning By-law, including By-law Nos 5626-14 and 5732-15. Page 20 of 62 October 10, 2024 6 of 7 Report No. MV-2024-25 Therefore, staff are of the opinion that the proposed variance does not meet the intent of the Zoning By-law. c) The proposed variance is not considered desirable for the appropriate development of the land The Town’s intent in regulating the location of Medical Marihuana Production Facilities is to ensure that surrounding sensitive land uses are not adversely impacted by potential noxious, nuisance and noticeable noise and emissions originating from said facilities. As discussed, the Town’s Zoning By-law indicates that Medical Marihuana Production Facilities are only permitted in lands zoned Business Park (E-BP), which are typically located along the Highway 404 corridor and not intended to be within proximity to residential uses, thereby reducing negative impacts in the surrounding area. The subject property, zoned General Employment (E2), explicitly prohibits the use of Medical Marihuana Production Facilities. As indicated though pre-consultation comments provided to the applicant, and discussed earlier herein, the Town considers the proposed use incompatible with the surrounding neighbourhood context, particularly as it relates to its proximity to residential areas, schools, places of worship, and recreational and community spaces. Staff believe it is paramount to ensure that the wellbeing and safety of residents, students, and those enjoying businesses and community spaces is maintained and protected. Therefore, staff cannot support the introduction of a Medical Marijuana Production Facility on the subject property, in such close vicinity to these sensitive uses. As such, staff are of the opinion that the requested variance is not considered desirable for the appropriate development of the land. d) The proposed variance is not considered minor in nature The question of the minor nature of a proposed variance can be related to its scale and impact on adjacent properties. In the opinion of Staff, the requested variance has the potential of causing noticeable nuisance odors for the surrounding sensitive land uses and existing neighbourhood as a whole. As indicated during the pre-consultation process, the Town identified that a Major Zoning By-law Amendment would be required to address the subject non-compliance and advised the applicant as such. It is the opinion of staff that permitting the subject variance would be in violation of the by-laws in place to ensure the safe regulation of Marihuana Production Facilities within the Town. Page 21 of 62 October 10, 2024 7 of 7 Report No. MV-2024-25 Staff are of the opinion that permitting a Marihuana Production Facility on the subject property would be incompatible with the nature of the surrounding uses, particularly sensitive land uses, including residential zones, places of worship, childcare facilities and schools, and other recreational and community gathering spaces. As such, staff are of the opinion that the requested variance is not minor in nature. Public Correspondence Written submissions were not received at the time of writing of this report. Should written submissions be received after the writing of this report, the Secretary Treasurer will provide the submission(s) to Committee members at the meeting. Conclusion Planning staff have reviewed the application with respect to Section 45(1) of the Planning Act, and are of the opinion that the requested variance does not meet the requirements of Section 45(1) of the Planning Act for granting of minor variances. Staff recommend denial of the requested variance. The onus is ultimately on the applicant to demonstrate why they should be granted relief from the requirements of the Zoning By-law and how they satisfy the four tests. Attachments Appendix ‘A’ – Site Plan and Elevations Page 22 of 62 SCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION 2024-05-12 12:46:00 AMCover Page Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A000 Author 05/05/24 Medical Marijuana Grow Facilities 95 Dunning AveAurora, ON L4G 0R2 Adjacent Property Zonings ISSUED FOR PLANNING AND ZONING STUDY -DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION Rev Description Date Page 23 of 62 F.R. F.R. F.R. F.R.F.R.1 STY.BRICK DWELLINGNo. 95BLOCK ADOOR SILL=267.89REGISTERED PLAN 488 BLOCK 'A' LOT 2 1LOT 36DRIVEWAY GRAVEL PADCONCRETEBOXHYDROANCHORTOP OF DITCH TOP OF DITCH CANADIAN NATIONAL R A I L W A Y DRIVEWAYGRAVELDRIVEWAY AREAASPHALTCONCRETE RETAINING WA L L CURBUTILITYPOLEUTILITYPOLEUTILITYPOLEISLANDPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEPADCONCRETEPADCONCRETECURBCURB CURBSTUMP D=0.30ANCHORCRW STEPDRIVEWAY AREAASPHALTFIRE HYDRANTFIRE HYDRANTUTILITYPOLECRW DRIVEWAY AREAASPHALTSTUMP D=0.30CONCRETE RETAINING WALL CONCRETE RETAINING WALL DRIVEWAY AREAASPHALTDRIVEWAY AREAASPHALTCONCRETE DRIVEWAY AREAANCHORANCHORPIPECONCRETE DRIVEWAY AREA CENTER LINE OF ROADCENTER LI N E O F R O A DCENTER LINE OF ROADEDGE OF ASPHALTEDGE OF ASPHALTIB(1017)(1017)SIB(L&P)SIB(1017)IB(1017)IB(1017)IB(1017)SIB(1017)SIB(1727)SIB(L&P)SIB(L&P)SIB(BENT)SIB (L&P)GASMETER(1017)SIB(1017)IB(1017)IB(1017)IBUTILITYPOLE GASMETERDRIVEWAY A R E A ASPHALT CONCRETE RETAINING WALLCONCRETE RETAINING WALLCURBLIGHTPOLEUTILITYPOLEANCHORLIGHTPOLELIGHTPOLELIGHTPOLELIGHTPOLECURBVALVEWATERANCHORUTILITYPOLEGASVALVECONCRETE DRIVEWAY CURB GUYCENTER OF DITC H DRIVEWAY GRAVEL ANTENNADRAINAGE SIGNSIGNANCHORHYDRO BOX GENERATOR BOXWIRE USED BASEIBIBIBIB(OU)SIB(1017)IB(1017)SIB(1017)SIB(1017)IB(1017)SIB(1017)SIB(1017)SIB(1017)SIB(1017)IB(1017)IB(1017)CC(1017)IB(1017)IB(1017)IB(1017)IB(1017)PK(1017)PK(1017)PKE D W A R D S T R E E T E N G E L H A R D D R I V ED U N N I N G A V E N U EP.I.N. 036 4 5 - 0 1 6 2 ( L T )INST 284277P.I.N. 0 3645-0062 (LT)P.I.N. 0 3645-0064 (LT)DEDICATED BY REGISTERED PLAN 487 20.10 WIDELOT 152 REGISTERED PLA N 2 4 6 INST 31608B (1STLY)INST 31608 B (2NDLY)INST 31608B (3RDLY)PART 5PLAN 64R-40202 PART 6PLAN 64R-7942 PART 3 PART 2 PLAN 64R - 7 9 4 2 PART 1 PLAN 65R-1318PART 2 PLAN 65R-2381 (BY LAW 2462-81)DEDICATED BY REGISTERED PLAN 488 PLAN 64R-7942 INST 182743REGISTERE'S COMPILED PLAN 10328INST 30 7 2 3 1(BY LA W 2 5 5 2 - 8 2 ) INST 61 5 8 6 APART 6PLAN 64R-40202PART 1 PART 4SUBJECTED TO EASEMEN T A S I N I N S T . Y R 9 6 2 1 1 P.I.N. 03645-00162 (LT) PLAN 65R-40202 PLAN 64R-40202PLAN 64R-40202PART 3PART 2LIMIT BETWEEN REGISTERED COMPILED PLAN 10328 AND R.P NO. 488PART 1 PLAN 65R-17425PART 5PLAN 64R-7942P.I.N. 0 3645-0004 (LT)PART 1, PLAN 65 R-17550P.I.N 03645-0076(LT)SUBJECTED TO INST R 239295PART 2PLAN 64R-40202PART 1, PLAN 65 R-40684PLAN 65R -40684PART 3PLAN 65R -40684PART 3PLAN 65R-40684SUBJECT TO A EASEMENT AS IN INST. R697446 E SUBJECT TO A EASEMENT AS IN INST. R695792 A N D R 7 1 7 6 5 9 SUBJECT TO A EASEMENT AS IN INS T . Y R 3 5 2 1 0 5 9 SUBJECT TO A EASEMENT AS IN INS T . Y R 3 5 2 1 0 5 9 SUBJECT TO A EASEMENT AS IN INST. YR3521059SUBJECT TO A EASEMENT AS IN INST. YR3521059SUBJECT TO A EXCLUSIVE TEMPORARY EASEMENT IN GROSS AS IN INST. YR3521059MAN HOLECHAIN LINK FENCE CBCBCBCBCBCBCBCBCBCBCBCBCBCBMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEV10 27005500 SEE PLAN15001800 629LS FH FIRE HYDRANT (REFER TO CIVIL DRAWINGS) LIGHT POLE (REFER TO ELECTRICAL DRAWINGS)-TO BE PROVIDED STOP SIGN (REFER TO PAVEMENT MARKING AND SIGNAGE PLAN) TACTILE INDICATOR BARRIER FREE PARKING (3.4M x 5.5M UNDERGROUND) VISITOR PARKING (2.7M x 5.5M UNDERGROUND) BICYCLE PARKING-SITE LEVEL TEXTURED CROSSWALK (REFER TO PAVEMENT MARKING AND SIGNAGE PLAN) LEGEND DC DEPRESSED CURB GAS METER HYDRO METER G H S.S. B.F. F.R. BARRIER FREE PARKING SIGN (REFER TO PAVEMENT MARKING AND SIGNAGE PLAN) FIRE ROUTE SIGN (REFER TO PAVEMENT MARKING AND SIGNAGE PLAN) NFHB NON FREEZABLE HOSE BIB-U/G TH-2 UNIT NUMBER EVCS ELECTRIC VEHICLE CHARGING STATION-U/G VISITOR PARKING (SITE LEVEL) (2.7M x 6.7M PARALLEL PARKING SPACE) CAST IRON GATE WITH DOOR SIAMESE CONNECTION (REFER TO MECHANICAL/CIVIL DRAWINGS) ENTRANCES/EXIT ENTRY DOOR OVERHEAD DOOR ENTRYWAL L MOUNTED BICYCLE PARKING-UG WALL MOUNTED 863 600 Maximum Fine $5000 For Enforcement call: (905)-458-3424 Maximum Fine $5000 For Enforcement call: (905)-458-3424 VAN ACCESSIBLE VAN ACCESSIBLE MOUNTING SIGNAGE FACE REQUIREMENTS DISABLED PARKING PERMIT SIGN NEAR A BUILDING FRONT TYPICAL MARKINGS ILLUSTRATED FOR STALL & SIDEWALK TYPICAL SUPPORT AND BASE FIRE ROUTE SIGN DETAIL FIRE ROUTE SIGNAGE AND INSTALLATION SPECIFICATIONS SIGN REQUIREMENTS INSTALLATION REQUIREMENTS 30.00 cm 2.54 cm 45.00cm SIGNS SHALL COMPLY WITH THE ATTACHED FIGURE 5 1.ALL SIGN SHALL HAVE APPROPRIATE RADIUS. CORNER AS PER DIAGRAM OR 4 2.CM. RADIUS. ALL SHARP EDGES REMOVED SIGN BLANKS SHALL COMPLETED SIGNS SHALL HAVE 11MM. X 18MM. SLOTTED HOLES TO 3.ACCEPT METRIC OR IMPERIAL MOUNTING WITH HOLES 3CM-12CM FROM OUTER EDGE OR AS PER DIAGRAM. CENTRE OF MOUNTING SLOTS SHALL BE EQUAL TO MULTIPLE OF 5.08CM (2 INCHES) CENTRALLY LOCATED ON BLANK. ON STEEL BLANKS, FABRICATIONS SHALL BE FABRICATED BEFORE GALVANIZING AS TO PREVENT CORROSION. ON ALUMINUM BLANKS, FABRICATING SHALL BE PERFORMED PRIOR TO PAINTING AND BAKING. FINISHED SIGNS AND SYMBOLS SHALL BE APPLIED TO 1.63MM UTILITY GRADE 4.ALUMINUM WITH BRIGHT WHITE MILL BAKED FINISH ON BOTH SIDES. ALL INKS SHALL BE FACES TO CONFORM TO REG. 486 OF THE HIGHWAY TRAFFIC ACT. 5.ALL LETTERING TO MEET M.T.O. STANDARDS 6.ALL COLOURS TO MEET M.T.O. STANDARDS 1.SHALL BE POSTED ON BOTH SIDES OF THE FIRE ROUTE FACING THE FLOW OF TRAFFIC AT A 45 DEGREE ANGLE, 2.13M (7FT) ABOVE GROUND LEVEL AND AT DISTANCES SO THEY CAN BE CLEARLY SEEN BY THE MOTORIST AND NOT MORE THAN 22.86M (75FT)APART. 2.MAY BE MOUNTED FLUSH ON THE BUILDING FACE ALONG THE FIRE ROUTE, 2.13M (7FT) ABOVE GROUND LEVEL AND AT DISTANCES SO THEY CAN BE CLEARLY SEEN BY THE MOTORIST AND NOT MORE THAN 15.24M (50FT) APART. 3. IF A FIRE ROUTE EXCEEDS 6M (19.6FT) IN WIDTH OR IN APPROVED CIRCUMSTANCES, POSTING OF SIGNAGE ON ONE SIDE OF THE ROUTE IS PERMISSIBLE. 4.SIGNS SHALL INDICATE WHERE THE FIRE ROUTE STARTS AND ENDS. IN SOME SITUATIONS WHERE BOTH NO STOPPING/NO PARKING SIGNS ARE REQUIRED, TWO SIGNS MAY BE REQUIRED ON THE SAME POST. 2014-0014 FIRE ACCESS ROUTE 2014-0014 FIRE ACCESS ROUTE CIRCLE TO BE RED IN COLOUR ON A WHITE BACKGROUND WITH BLACK LETTERING 30.00 cm 45.00 cm 2.54 cm 2.54 cm 2.54 cm NUTS WITH FLAT WASHERS ON BOTH SIDES. ANCHORS WITH TWO GALVANIZED 12mm HEX HEAD BOLTS AND THE SIGN FACE MUST BE SECURED TO A POST OR WALL SPECIFICATION SIGN BLANK WITH TOP AND BOTTOM MOUNT HOLES. TO MTO 0.064 INCH GAUGE ALUMINUM OR 15 GAUGE GALVANIZE STEEL THE HEAD OR TOP END OF EACH SPACE. NOT MORE THAN 2.0m FROM THE FACE OF THE CURB OR AT THE REQUIRED SIGN MUST BE MOUNTED AT LEAST 0.6m AND APPLICABLE. SUCH AS OPEN ROW IN PARKING LOT. ALL HANDICAPPED PARKING STALLS SHALL BE DESIGNATED BY ONE SIGN PER SPACE, BACK TO BACK MOUNTED WHERE WHERE AN UNOBSTRUCTED BUILDING FACE IS LOCATED NOT MORE SIGNS MUST NOT OBSTRUCT THE SIDEWALK. THAN 2.50m FROM THE FACE OF THE CURB AT THE HANDICAPPED SPACE. THE SIGNS MAY BE MOUNTED ON THE BUILDING FACE. THAN 2% ACROSS THE STALL WIDTH. * SURFACE SLOPE LESS THAN 5% LONGITUDINALLY AND LESSOR AS PER CITY REQUIREMENTOR AS PER CITY REQUIREMENT 34006000STRIPE AMBER PAINT 100 WIDE OR SIDEWALK Rb-93 SIGN CONDENSED. BORDER. SPACE LOCATIONS. DISABLED PARKING ASSOCIATED WITH AND CURB CUT, BUILDING FACES WHEELCHAIR RAMP 30mm BLACK LEGEND HELVETICA BOLD BACKGROUND AND OUTLINE. 125mm BLUE SQUARE REFLECTIVE WHITE REFLECTIVE SYMBOL AND ENGINEERING GRADE SCOTCHLITE FILM. WHITE REFLECTIVE BACKGROUND E.G. STROKE. 15 RED REFLECTIVE (150mm O.D.) BACKGROUND CIRCULAR 20 RED REFLECTIVE AND BLACK BORDER BLACK LETTER `P' 75 mm HEIGHT (300X450) SINGLE FACE Rb-93 SIGN 3003001700 MINIMUM -2000 MAXIMUM450O N L Y B Y P E R M I T TIMREPYB YLNO G 35 10 25 30 15 M DTOS 3IN-9COERb SUPPORT) FOOTING (OR EQUIVALENT FIRM PLACE IN 300mm DIA. CONCRETE PIPE. POST TO BE CAST IN GALVANIZED STANDARD STEEL SIGN POLE OR 75mm DIA. TREATED WOOD. U-CHANNEL 100mm X 100mm PRESSURE AROUND FOOTING EXPANSION JOINT BLACK LETTERING WHITE REFLECTIVE BACKGROUND AND 1500 PARKING SPACE PAINTED WITH A NON-SLIP PAINT IN BRIGHT BLUE, OVERLAID WITH THE INTERNATIONAL SYMBOL OF ACCESS FOR THE DISABLED WHICH IS: -AT LEAST 1000mm LONG -LOCATED IN THE CENTRE OF THE SPACE -PAINTED WHITE OR YELLOW 150u 340150550 260150550 270550 TYPE "A" PARKING SPACE MIN TYPE "B" PARKING SPACE MIN TYPICAL PARKING SPACE MIN LOT AREA GROSS BUILDING AREA (Total) BUILDING AREA (Scope of job) BUILDING COVRAGE (Total) BUILDING COVRAGE (Scoep of job) VEHICLE PARKING TOTAL PROJECT PARKING TOTAL GARBAGE LOADING 3.6W x 9L x 4.2H (CLEAR) BICYCLE PARKINING LONG TERM LOCKERS 1500W x 900L (MIN) BUILDING HEIGHT (EXCLUDES MECH .PH) MIN. SETBACKS NORTH WEST SOUTH (FRONT) EAST 18.630 m 26845.311 SQM 5002.012 SQM = 18.64 % 69 (UNDERGROUND) 1.712 m 5.080 m 10.140 m 3.144 m 63.10 % 23.13 % 16940.607 SQM 6210.875 SQM - - 4902.692 SQM = 18.26 % N/A 3.000 m 5.500 m 5.500 m 5.500 m LANDSCAPE AREA HARD SURFACE SOFT SURFACE GREEN ROOF TOTAL LANDSCAPE 9904.704 SQM = 36.90% (SOFT AND HARD) AMENITY SPACES REQUIERD PROVIDED TOTAL AMENITY REQUIERD PROVIDED BARRIER FREE PARKING 1 TYPE "A" SPACE 1 TYPE "B" SPACE 1 TYPE "A" SPACE 1 TYPE "B" SPACE REQUIERD PROVIDED TOTAL BICYCLES 1 P/U REQUIERD=68 REQUIERD PROVIDED REQUIERD PROVIDED OBC REFERENCEITEMONTARIO BUILDING CODE DATA MATRIX, PART 11 1.BUILDING AREA (sq.m.): 2.NUMBER OF STOREYS: 4. 5.BUILDING CLASSIFICATION: 11.SPRINKLER SYSTEM PROPOSED: 12.STANDPIPE REQUIRED: 13.FIRE ALARM REQUIRED: 16.PERMITTED CONSTRUCTION: 17.MEZZANINE(s) AREA (sq.m.): 18.OCCUPANT LOAD BASED ON: 19.BARRIER FREE DESIGN: 20.HAZARDOUS SUBSTANCES: 21.REQUIRED FIRE RESISTANCE RATING (FRR): 22.OTHER, DESCRIBE: NEW: TOTAL: GROSS AREA (sq.m.): ABOVE GRADE: BELOW GRADE: 3.HEIGHT OF BUILDING (m):___ 1.1.3.2 3.2.1.1 1.1.3.2 ___ ___TOTAL: ___ ___ ___ ___ 1.1.3.2 3.2.1.1 NUMBER OF STREETS / ACCESS ROUTES:___3.2.2.10 3.2.5.5 GROUP __, DIVISION __, UP TO ___ STOREYS ________ ENTIRE BUILDING BASEMENT ONLY IN LIEU OF ROOF RATING NOT REQUIRED 3.2.1.5 3.2.2.17 YES NO 3.2.9 YES NO 3.2.4 14.WATER SERVICE / SUPPLY IS ADEQUATE: YES NO 3.2.5.7 15.HIGH BUILDING YES NO 3.2.6 COMBUSTIBLE NON-COMBUSTIBLE ACTUAL CONSTRUCTION:COMBUSTIBLE NON-COMBUSTIBLE ________ ___________ BASEMENT: 1st. FLOOR: sq.m. / PERSON BUILDING DESIGN ___LOAD:___PERSONS ___LOAD:___PERSONS MEZZANINE: 2nd FLOOR: ___LOAD:___PERSONS ___LOAD:___PERSONS ________ 3.1.16 ________ YES NO, EXPLANATION:___3.8 YES NO 3.3.1.2.(1) 3.3.1.19.(1) ________ HORIZONTAL ASSEMBLIES FRR (HR's) LISTED DESIGN No. or DESCRIPTION (SB-2) FLOORS: ROOF: MEZZ.: ___ ___ ___ HOURS HOURS HOURS ___ ___ ___ SUPPORTING MEMBERS FRR (HR's) LISTED DESIGN No. or DESCRIPTION (SB-2) FLOORS: ROOF: MEZZ.: ___ ___ ___ HOURS HOURS HOURS ___ ___ ___ ___ DESCRIBE EXISTING USE: CONSTRUCTION INDEX: HAZARD INDEX: NOT APPLICABLE (NO CHANGE OF MAJOR OCCUPANCY) 11.2.1 T 11.2.1.1A T 11.2.1.1B to N ___ ___ ___ 6.ALTERATION TO EXISTING BUILDING IS:BASIC RENOVATION EXTENSIVE RENOVATION 11.3.3.1 11.3.3.2 7.REDUCTION IN PERFORMANCE LEVEL:STRUCTURAL: BY INCREASE IN OCCUPANT LOAD: 11.4.2.1 11.4.2.2 BY CHANGE IN MAJOR OCCUPANCY: PLUMBING: SEWAGE-SYSTEM: 11.4.2.3 11.4.2.4 11.4.2.5 YES YES YES YES YES NO NO NO NO NO 8.COMPENSATING CONSTRUCTION:STRUCTURAL:11.4.3.2NO YES, EXPLANATION: INCREASE IN OCCUPANT LOAD: 11.4.3.3NO YES, EXPLANATION: CHANGE IN MAJOR OCCUPANCY: 11.4.3.4NO YES, EXPLANATION: PLUMBING:11.4.3.5NO YES, EXPLANATION: SEWAGE-SYSTEM:11.4.3.6NO YES, EXPLANATION: ___ ___ ___ ___ ___ 9.COMPLIANCE ALTERNATIVES PROPOSED: YES (GIVE NUMBER(S)): NO 11.5.1___ 10.ALTERNATE MEASURES PROPOSED: YES, EXPLANATION: NO 11.5.2___ EXISTING: NEW: EXISTING:___ ___ T.B.D SCOPE OF JOB OUT OF SCOPE 2490.920m2 73.399m2 240.762m2 272.421m2 639.261m2 1285.249m2 3464.624m21200.541m2 237.527m2 6210.875m2 10729.732m2 SCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION As indicated 2024-05-12 12:46:02 AMZoning and DataMatrix Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A001 Author 05/05/24 PARKING DIAGRAMS ZONING INFORMATION TABLEONTARIO BUILDING MATRIX LEGEND HARD & SOFT LANDSCAPE DIAGRAM Rev Description Date Page 24 of 62 CBCBCBCBCBCBCBCBCBCBCBCBCBCBMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEMAN HOLEBLOCK 'A' LOT 2 1LOT 36REGISTERED PLAN 4 8 8 1 STY.BRICK DWELLINGNo. 95BLOCK ADOOR SILL=267.89REGIONAL MUNICIPALITY OF YORKPART OF BLOCK AREGISTERED PLAN 488CITY OF AURORAMETRICELEVATION NOTEBEARING NOTELEGENDP.I.N. 03 6 4 5 - 0 1 6 2 ( L T )INST 284277P.I.N. 03645-0062 (LT)P.I.N. 03645-0064 (LT)DEDICATED BY REGISTERED PLAN 487 20.10 WIDELOT 152 REGISTERED P L A N 2 4 6 INST 31608B (1STLY)INST 31608B (2NDLY)INST 31608B (3RDLY)PART 5 PLAN 64R-40202 PART 6 PLAN 64R-7942 PART 3 PART 2 PLAN 6 4 R - 7 9 4 2 PART 1 PLAN 65R-1318PART 2 PLAN 65R-2381 (BY LAW 2462-81)DEDICATED BY REGISTERED PLAN 4 8 8 PLAN 64R-7942 INST 182743REGISTERE'S COMPILED PLAN 10328INST 3 0 7 2 3 1(BY LA W 2 5 5 2 - 8 2 ) INST 6 1 5 8 6 APART 6PLAN 64R-40202PART 1 PART 4SUBJECTED TO EASEM E N T A S I N I N S T . Y R 9 6 2 1 1 P.I.N. 03645-00162 (LT) PLAN 65R-40202 PLAN 64R-40202PLAN 64R-40202PART 3PART 2LIMIT BETWEEN REGISTERED COMPILED PLAN 10328 AND R.P NO. 488PART 1 PLAN 65R-17425PART 5PLAN 64R-7942P.I.N. 03645-0004 (LT)PART 1, PLAN 65R-17550P.I.N 03645-0076(LT)SUBJECTED TO INST R239295PART 2PLAN 64R-40202PART 1, PLAN 65R-40684PLAN 65R-40684PART 3PLAN 65R-40684PART 3PLAN 65R-40684SUBJECT TO A EASEMENT AS IN IN S T . R 6 9 7 4 4 6 E SUBJECT TO A EASEMENT AS IN IN S T . R 6 9 5 7 9 2 A N D R 7 1 7 6 5 9 SUBJECT TO A EASEMENT A S I N I N S T . Y R 3 5 2 1 0 5 9 SUBJECT TO A EASEMENT A S I N I N S T . Y R 3 5 2 1 0 5 9 SUBJECT TO A EASEMENT AS IN INST. YR3521059SUBJECT TO A EASEMENT AS IN INST. YR3521059SUBJECT TO A EXCLUSIVE TEMPORARY EASEMENT IN GROSS AS IN INST. YR3521059E D W A R D S T R E E T E N G E L H A R D D R I V ED U N N I N G A V E N U EDRIVEWAY GRAVEL PADCONCRETEBOXHYDROANCHORTOP OF DIT C H TOP OF DIT C H CANADIAN NATIONA L R A I L W A Y DRIVEWAYGRAVELDRIVEWAY AREAASPHALTCONCRETE RETAINI N G W A L L CURBUTILITYPOLEUTILITYPOLEUTILITYPOLEISLANDPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEUTILITYPOLEPADCONCRETEPADCONCRETECURBCURB CURBSTUMP D=0.30ANCHORCRW STEPDRIVEWAY AREAASPHALTFIRE HYDRANTFIRE HYDRANTUTILITYPOLECRW DRIVEWAY AREAASPHALTSTUMP D=0.30CONCRETE RETAINING WALL CONCRETE RETAINING WALL DRIVEWAY AREAASPHALTDRIVEWAY AREAASPHALTCONCRETE DRIVEWAY AREAANCHORANCHORPIPECONCRETE DRIVEWAY AREA CENTER LINE OF ROADCENTER L I N E O F R O A DCENTER LINE OF ROADEDGE OF ASPHALTEDGE OF ASPHALTIB(1017)(1017)SIB(L&P)SIB(1017)IB(1017)IB(1017)IB(1017)SIB(1017)SIB(1727)SIB(L&P)SIB(L&P)SIB(BENT)SIB (L&P)GASMETER(1017)SIB(1017)IB(1017)IB(1017)IBUTILITY POLE GASMETERDRIVEW A Y A R E A ASPHAL T CONCRETE RETAINING WALLCONCRETE RETAINING WALLCURBLIGHTPOLEUTILITYPOLEANCHORLIGHTPOLELIGHTPOLELIGHTPOLELIGHTPOLECURBVALVEWATERANCHORUTILITYPOLEGASVALVECONCRETE DRIVEWAY CURB GUYCENTER OF D I T C H DRIVEWAY GRAVEL ANTENNADRAINAGE SIGNSIGNANCHORHYDRO BOX GENERATOR BOXWIRE USED BASEIBIBIBIB(OU)SIB(1017)IB(1017)SIB(1017)SIB(1017)IB(1017)SIB(1017)SIB(1017)SIB(1017)SIB(1017)IB(1017)IB(1017)CC(1017)IB(1017)IB(1017)IB(1017)IB(1017)PK(1017)PK(1017)PKMAN HOLEJOB No. : XX-XXXXCHK BY: ESDWN BY: AMDISTANCES SHOWN ON THIS PLAN ARE IN METERSAND CAN BE CONVERTED TO FEET BY DIVIDING BY 0.3048BEARINGS ARE ASTRONOMIC AND ARE REFERRED TO THE EASTERLY LIMITOF BLOCK 'A' AS SHOWN ON PLAN 65R-17425 HAVING A BEARINGOF N12°36'00"W.PDENOTESREGISTERED PLAN 488P1DENOTESPLAN 65R-40684D1DENOTESINSTRUMENT No. XXXXXXXXDENOTESSURVEY MONUMENT FOUNDDENOTESSURVEY MONUMENT PLANTEDIBDENOTESIRON BARSIBDENOTESSTANDARD IRON BARPKDENOTESSURVEYORS NAIL SET IN WASHEROUDENOTESORIGIN UNKNOWNMHDENOTESMANHOLEBCDENOTESBEGINNING OF CURVEBOCEDENOTESBOTTOM OF CURB ELEVATIONOHDENOTESOVERHEAD UTILITY CABLESDTDENOTESDECIDUOUS TREECTDENOTESCONIFEROUS TREELSDENOTESLIGHT STANDARDGFEDENOTESGARAGE FLOOR ELEVATIONINVDENOTESINVERT ELEVATIONHYDDENOTESFIRE HYDRANTCONCRETE RETAINING WALLDENOTESCRWRETAINING WALLDENOTESRWSTONE RETAINING WALLDENOTESSRWWOOD RETAINING WALLDENOTESWRWTOP OF WALL ELEVATIONDENOTESTOWCHAIN LINK FENCEDENOTESCLFBOARD FENCEDENOTESBFFINISHED FLOOR ELEVATIONDENOTESFFECCDENOTESCUT CROSSMETAL FENCEDENOTESMFTOP OF CONCRETE CURB ELEVATIONDENOTESTOCTCDENOTESTANGENT OF CURVEPRCDENOTESPOINT OF REVERSE CURVEECDENOTESEND OF CURVECHAIN LINK FENCEL&PDENOTESLloyd & Purcell Ltd. O.L.S1727DENOTESE.R.GARDEN Ltd. O.L.SELEVATIONS ARE GEODETIC AND ARE DERIVED FROM GPS OBSERVATIONSUSING SOKKIA TOPNET REAL TIME NETWORK (RTN) AND ARE BASEDON NRCAN HTv2.0 GEOID SEPARATION MODEL.1017DENOTESCALLON DIETZ INC. O.L.SP1DENOTESPLAN 65R-40202P1DENOTESPLAN 65R-7942P1DENOTESPLAN 65R-17425P1DENOTESPLAN XX-XXXXX269.82269.41269.50269.96270.83272.04272.10272.13271.94272.26 272.06272.44272.71272.87272.83272.63272.18271.87272.17271.77270.71270.11270.69269.82270.10269.52 269.48270.66270.25 269.21269.57269.55268.68 269.39 269.86270.03270.07269.86269.85269.93269.72270.06269.91270.32270.43270.58270.21270.23270.49270.33270.09269.80270.01269.76269.46269.71269.79269.67269.56269.48266.92266.99266.88266.86265.66266.20266.39265.75265.79267.66268.60268.68268.67268.31268.04 267.90267.73267.64267.50267.28 267.19267.17265.68 265.66265.88266.39266.90266.76266.81266.41265.94 266.18266.52265.50269.13267.77265.80265.27266.90266.94266.55 266.60 266.94266.82268.16268.88268.38271.14271.23270.91270.12270.81 269.49270.97269.43268.18267.44267.33267.26267.09266.97 266.90270.48 270.65 270.80270.75271.37267.69 267.71 267.73 267.82 267.85 267.84267.21267.47267.72269.71269.18268.35 267.66 268.07 269.36270.05270.72 269.74269.71269.78271.50270.78271.69270.85 271.81269.85270.40269.17269.27266.96268.47268.45265.67265.27265.15264.95265.30266.78 266.78267.43270.01270.63270.33268.25267.69268.19268.48267.18 267.13265.66266.04266.00265.24266.91266.93268.11272.00271.19270.76270.62270.52270.00269.41268.62268.08266.80267.02267.55265.42265.93266.01266.19264.57264.28265.30265.07265.29266.15267.40268.71269.15272.15272.13272.16272.13271.86272.00272.01 269.72267.17267.18267.18267.87267.86268.50 268.49268.49269.99270.18270.18271.17269.55269.26269.76270.06269.09268.53268.06267.76268.14268.56269.15267.54267.56 267.64267.82267.87267.82267.80267.76267.67267.60267.85267.87267.77269.25268.80267.72267.52269.12269.25268.73270.26268.11268.12268.08269.91269.91269.89269.89269.90269.88272.36272.36271.39270.81270.71270.64270.62270.64270.52270.35270.21269.88269.69269.52269.23269.68269.68269.62269.60269.56269.60269.67269.75269.36269.40269.43269.45269.72269.71269.73269.74 269.75269.76269.77269.00269.05268.28268.27268.61266.93266.99 267.39267.87268.10268.21268.31268.21268.40269.19266.60266.75266.86266.25266.25265.95265.58265.52265.54265.54265.62269.59 269.34269.20269.31269.45269.54269.35269.44269.42269.58269.98269.41269.76269.69269.60269.60269.71269.64269.80270.61270.61270.13269.58269.70270.29270.53269.87269.59 269.81270.18270.24270.36271.30272.37272.24271.65271.10270.76270.64269.44269.41268.99268.70268.51267.88267.88267.77266.99266.95266.90266.92266.29266.31269.43269.51269.66269.64269.65269.68269.81269.68269.32268.32268.34267.95267.98267.55 267.66 267.13 267.03267.29266.85267.01 266.85 266.56266.42 266.33266.23265.89266.23266.33 266.33265.81266.69265.82266.64266.67266.89267.05266.97267.68 268.19 268.66269.25268.73 268.52 268.27 267.95268.05267.93267.82267.75268.33 269.06268.48267.73266.85265.70265.44265.34264.94265.01265.07265.12265.47265.80265.83265.74265.47265.51265.33265.39265.56265.73265.83 265.98266.11265.51265.77265.97266.07266.21266.49266.74267.02 267.44267.46268.06268.56269.31269.51270.06 270.38270.50270.49270.69271.26272.64269.67269.48269.33269.33269.43269.59266.02265.95265.94265.93265.91265.78265.70265.79265.66265.54265.46265.63265.54265.52265.53265.40 265.13 265.14265.26265.64265.98267.09267.14269.91268.01267.59267.80267.53268.55269.82267.14267.15271.60272.23269.76272.72266.03266.16269.31268.80267.62266.15266.05267.62269.01271.08268.93271.59269.06268.79272.48SCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION 1 : 500 2024-05-12 12:46:02 AMProperty Survey Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A002 Author 05/11/24 1 : 500 Property Survey1 ISSUED FOR ZONING & PLANNING STUDY ASE+J INC.ARCHITECT IS NOT RESPONSIBLE FOR ANY DISCREPANCY IN THE PROPERTY SURVEY. ANY PARTIES INCLUDING OWNERS, CLIENTS, CONSULTANTS, PLANNERS, OR CONTRACTORS ARE RESPONSIBLE FOR VERIFYING & CHECKING THE ACCURACY OF THE SURVEY DURING BUILDING PERMIT AND CONSTRUCTION Rev Description Date Page 25 of 62 1200 MIN.400 VARIES 000.0 SLOPE FINISHED FLOOR 10 REINFORCED CONCRETE SLAB ON GRADE (SEE STRUCTURAL DWGS.) CONC. SLAB (SEE STRUCT. DWGS.) 75mm RIGID INSULATION EXTEND 900mm VERT. & HORIZ. BELOW FINISHED GRADE (R=15 TYP.) CONC. FOOTIG. (SEE STRUCTURAL DWGS.) CONT. MOISTURE BARRIER UNDER SLAB. CONC. FOUND. WALL (SEE STRUCTURAL DWGS.) 300mm OF 19mm GRANULAR GRAVEL COMPACTED TO 100% SPMDD SLOPE 1 : 7 . 5 MAX. 15050 505045025 MAX.150300100100 COMPACTED GRAN.FILL ASPHALT SURFACE POURED CONC. CURB PARTING STRIP NEW SIDEWALK - POURED CONCRETE CONCRETE OR BRICK PAVERS (SEE SITE PLAN) COMPACTED GRANULAR FILL 13MM DIA. DOWELS 450MM LONG ACROSS 13MM EXPANSION JOINTS @ 5 500MM O.C. ONE END OF DOWEL SHALL BE LUBRICATED WITH A RELEASING AGENT. 100100 505030015015050 450POURED CONCRETE CURB ASPHALT SURFACE COMPACTED GRANULAR FILL FINISH CURB ELEVATION (SEE LANDSCAPE PLAN) PARTING STRIP NEW SIDEWALK -UNIT PAVERS CONCRETE OR BRICK PAVERS (SEE LANDSCAPE PLAN) COMPACTED GRANULAR FILL 13MM ∅DOWELS 450MM LONG ACROSS 13MM EXPANSION JOINTS @ 5485MM O.C. ONE END OF DOWEL SHALL BE LUBRICATED WITH A RELEASING AGENT.1503005050450100100 1505050 FINISH CURB ELEVATION ( SEE GRADING PLAN ) PLANT MATERIALS ( SEE LANDSCAPE DRAWINGS ) 13MM DIA. DOWELS 450MM LONG ACROSS 13MM EXPANSION JOINTS @ 5 500 MM O.C. ONE END OF DOWEL SHALL BE LUBRICATED WITH A RELEASING AGENT. POURED CONCRETE CURB COMPACTED GRANULAR FILL ASPHALT SURFACE 10001200500 ROUND TOP FOOTING 200MM CONCRETE SLAB ON GRANULAR FILL PAINTED 200MM DIA. STEEL PIPE CONC. FILLED ROUNDED TOP POURED CONC. FOOTING 01 01 02 02 03 03 04 04 05 05 06 06 07 07 09 09 10 10 11 11 12 12 13 13 14 14 B B C C D D E E F F G G H H I I K K L L M M N N A A J J 579 1071 986 2710 1575 1063 2708 3120 300 2340 2800 48228811009636314741152125636112436708620579 1071 986 2710 1575 1063 2708 3120 300 2340 2800 2223 48228811009636314741152125636112436708620NSITE PLAN SCALE 1:500 08 08 SCOPE OF JOB OUT OF SCOPE 34115432330562936403 340 2789204246843214044038 5553 4980 1000260 SCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION As indicated 2024-05-12 12:46:04 AMSite Plan Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A003 Author 05/05/24 Typical steel bollard N.T.S Typical, Con N.T.S Section Con Curb N.T.S Depressed Pad N.T.S Concrete Pad N.T.S Dimensions are to be verified by contractors during the permit process this dimension has been prepared for zoning and site planning review Rev Description Date Page 26 of 62 UP UP DN DN 01 01 02 02 03 03 04 04 05 05 06 06 07 07 B B C C D D E E F F G G H H I I K K L L A A J J Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room Medical Marijuana Grow Room 579 1071 986 2710 1575 1063 1050 775482288110096363147411521256361Open Area Corridor 121450110250105550106050210501575 50 936 50 980 50 820 50 2335 50 1013 50 992 1211501102501055509135035711385027550702504 50 1059 50 382 50 550 50 1600 50 1170 50 225 50 1006 50 1013 50 225 50 542 50 114 1479501576501544501320501200508885027050110250105550913501050505013205015445018263062702304742 A004 Sim 08 08 1220 600 1700 1575 50 2336 50 1260 STG-ROOMSTG-ROOMSTG- ROOM RoomRoom Open Seating Area For Lunch Open Medical Marijuana Grow area Open Medical Marijuana Grow area Open Medical Marijuana Grow area Open Medical Marijuana Grow area EMPTY SPACE EMPTY SPACE EMPTY SPACE EMPTY SPACE EMPTY SPACE Electrical panel area Electrical panel area Packing Room GAS Out of Scope N07 07 H H I I K K L L J J Men Restroom Women Restroom Room 6355071650473504845011050 Room 08 08 SCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION As indicated 2024-05-12 12:46:04 AMGround Floor Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A004 Author 05/05/24 1 : 250 Ground Floor Plan -Callout 11 Dimensions are to be verified by contractors during the permit process this dimension has been prepared for zoning and site planning review 1 : 251 Level 02-Mez2 Rev Description Date Page 27 of 62 UP UP 01 01 02 02 03 03 04 04 05 05 06 06 07 07 B B C C D D E E F F G G H H I I K K L L A A J J 579 1071 986 2710 1575 1063 775482288110096363147411521256361712 50 1154 880 1613 50 382 50 4751 50 1288 592 50114 730 883 50 278 50 570 50 91350105550110250270508875030950668468790 560 270Demolition walls Demolition walls 08 089135015761007965089100117261644420950128942621739611306503635 Out of Scope NSCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION 1 : 250 2024-05-12 12:46:04 AMExisting Plan Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A005 Author 05/05/24 1 : 250 Existing Ground FLoor1 Dimensions are to be verified by contractors during the permit process this dimension has been prepared for zoning and site planning review EXISTING WALLS TO BE VERIFIED BY CONTRACTOR-THIS SET HAS BEEN ISSUED FOR ZONING AND SITE PLANNING NOT FOR PERMIT AND CONSTRUCTION Rev Description Date Page 28 of 62 UP UP 01 01 02 02 03 03 04 04 05 05 06 06 07 07 09 09 10 10 11 11 12 12 13 13 14 14 B B C C D D E E F F G G H H I I K K L L M M N N 579 1071 986 2710 1575 1063 2708 3120 300 2340 2800 7754822881100963631474115212563611243670939511007205013205015445016262003062702301159 382 600 1700 3202251320 210504 Out of Scope A A 1220 3571055J J 820980936 1013 106010551102320154410509131613 13201006 Open Area Corridor 1 A004 120286.100 m² Medical Marijuana Grow Room 102.900 m² Medical Marijuana Grow Room 98.314 m² Medical Marijuana Grow Room 147.698 m² Medical Marijuana Grow Room 74.354 m² Medical Marijuana Grow Room 207.900 m² Medical Marijuana Grow Room 189.029 m² Medical Marijuana Grow Room 107.343 m² Medical Marijuana Grow Room 106.837 m² Medical Marijuana Grow Room 111.594 m² Medical Marijuana Grow Room 110.894 m² Medical Marijuana Grow Room 128.931 m² Medical Marijuana Grow Room 176.315 m² Medical Marijuana Grow Room 60.608 m² Medical Marijuana Grow Room 88.356 m² Medical Marijuana Grow Room 191.421 m² Medical Marijuana Grow Room Scope of Job 08 08 166.335 m² Room 109.747 m² Room Open Medical Marijuana Grow area Open Medical Marijuana Grow area Open Medical Marijuana Grow area Open Medical Marijuana Grow area EMPTY SPACE EMPTY SPACE EMPTY SPACE EMPTY SPACE EMPTY SPACE Electrical panel area Electrical panel area Packing Room GAS Open Seating Area For Lunch NSCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION 1 : 500 2024-05-12 12:46:05 AMProposal Plan -Ground Floor Plan Project Number Medical Marijuana Grow Room 95 Dunning Ave E.J A006 E.O 05/05/24 1 : 500 Ground Floor Plan1 Dimensions are to be verified by contractors during the permit process this dimension has been prepared for zoning and site planning review PROPOSAL WALLS ARE APPROXIMATE AND NEED TO BE VERIFIED BY THE CONTRACTOR -THIS SET HAS BEEN ISSUED FOR ZONING AND SITE PLANNING NOT FOR PERMIT AND CONSTRUCTION Rev Description Date Page 29 of 62 M.E M.EM.E M.E M.EM.E M.EM.EM.EM.EM.EM.E M.EM.E M.EM.E M.E M.EM.EM.EM.E M.E M.E M.E M.E M.E M.EM.E01 01 02 02 03 03 04 04 05 05 06 06 07 07 09 09 10 10 11 11 12 12 13 13 14 14 B B C C D D E E F F G G H H I I K K L L M M N N A A J J 08 08 579 1071 986 2710 1575 1063 2708 3120 300 2340 2800 48228811009636314741152125636112436708620290 150 320 10 150 490 490 490 950 579 1071 986 2710 1575 1063 2708 3120 300 2340 2800 48228811009636314741152125636112436708620NSCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION 1 : 500 2024-05-12 12:46:05 AMRoof Plan Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A007 Author 05/05/24 1 : 500 Roof Plan1 Rev Description Date Page 30 of 62 Ground Floor Plan 0 Level 01 350 Level 02-Mez 500 Level 03 670 Level 04 840 Level 05 1300 BCDEFGHIKLMN AJ 460170170150350Ground Floor Plan 0 Level 01 350 Level 02-Mez 500 Level 03 670 Level 04 840 Level 05 1300 010203040506070910111213 35015017017046008 Ground Floor Plan 0 Level 01 350 Level 02-Mez 500 Level 03 670 Level 04 840 Level 05 1300 01 02 03 04 05 06 07 09 10 11 12 13 460170170150350STANDING SEAM CLADDING WHITE BRICK MASONRY BRICK WALL STUCCO CLADDING CONCRETE RETAIN WALL M. CONCRETE BLOCK BRICK WALL BRICK WALL BRICK WALL 08 Ground Floor Plan 0 Level 01 350 Level 02-Mez 500 Level 03 670 Level 04 840 Level 05 1300 B C D E F G H I K L M NAJ 365150170170460SCALE (@ A1) CHECKED BY TITLE PROJECT NUMBER CLIENT PROJECT DRAWING NUMBER REV DRAWN BY DATE ASE + J INC ARCHITECT WWW.ASEJ.CA INFO@ASEJ.CA TELL: 647-937-5225 ISSUED FOR PLANNING AND ZONING STUDY & DOES NOT HAVE ANY VALUE FOR BUILDING PERMIT AND CONSTRUCTION DIMENSIONS ARE NEARLY ACCURATE AND WILL NEED TO BE ACCURATE VERIFIED DURING BUILDING PERMIT & CONSTRUCTION APPLICATION 1 : 350 2024-05-12 12:46:08 AMElevations Project Number Medical Marijuana Grow Room 95 Dunning Ave Checker A008 Author 05/05/24 1 : 350 South Elevation1 1 : 350 East Elevation2 1 : 350 West Elevation3 1 : 350 North Elevation4 ELECTRICAL POWER TRANSFER EQUIPMENTS BRICK WALL M. CONCRETE BLOCK CONCRETE RETAIN WALL LOADING SPACE 3.6M x 9M LOADING SPACE 3.6M x 9M STANDING SEAM CLADDING BRICK WALL STUCCO CLADDING BRICK WALL BRICK WALL BRICK WALL CONCRETE RETAIN WALL WHITE BRICK MASONRY M. CONCRETE BLOCK BRICK WALL M. CONCRETE BLOCK SIAMESE CONNECTION Rev Description Date Page 31 of 62 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 4 -27 _______________________________________________________________________________________ Subject: Minor Variance Application Ashish Inamdar 69 Kennedy Street E PLAN 332 LOT 15 File: MV-2024-27 Prepared by: Felix Chau, Planner Department: Planning and Development Services Date: October 10, 2024 _______________________________________________________________________________________ Application The owner/applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the construction of a two-storey detached dwelling and an accessory structure (cabana) in the rear yard. The following relief is being requested: a) Section 24.497.3.3 of the Zoning By-law permits a maximum gross floor area of 370.0 m2. The applicant is proposing a two-storey detached dwelling unit with a gross floor area of 452.5 m2. b) Section 24.497.3.3 of the Zoning By-law requires a maximum building footprint of 235 m2. The applicant is proposing a two-storey detached dwelling unit with a footprint of 254 m2. c) Section 24.497.5 of the Zoning By-law requires and integral garage to be flush with, or set back from, the main front wall of the detached dwelling. The applicant is proposing an integral garage projecting beyond the main front wall of the detached dwelling. d) Section 24.497.8 of the Zoning By-law requires max gross floor area of an accessory detached structure to be 40 m2. The applicant is proposing an accessory structure with 46.1 m2 gross floor area. Page 32 of 62 October 10, 2024 2 of 10 Report No. MV-2024-27 e) Section 4.12.2 (b) of the Zoning By-law requires a minimum distance separation of 1.2 m from the waters edge of the pool to any buildings and structures. The applicant is proposing an accessory structure with 0.0 m distance separation. f) Section 4.12.2 (b) of the Zoning By-law requires a minimum distance separation of 1.2 m from the waters edge of the pool to any buildings and structures. The applicant is proposing a rear covered deck with 0.5 m distance separation. Background Subject Property and Area Context The subject lands are municipally known as 69 Kennedy Street East and it is located on the south side of Kennedy Street East, east of Wells Street. The subject lands currently feature a one-storey detached dwelling which is proposed to be demolished as part of the redevelopment of the lands. The subject lands have an approximate lot area of 1,062.8 m2 (11,440 ft2) and an approximate lot frontage of 15.8 m2 (52 ft2). Mature trees and vegetation exist in the front and the rear of the subject lot. Proposal The applicant is proposing to demolish the existing one-storey detached dwelling and construct a two-storey detached dwelling with a building footprint of 254 m2 (2,734 ft2). The applicant also proposes to construct a private swimming pool and an accessory structure (cabana) in the rear yard. Official Plan The subject property is designated ‘Stable Neighbourhoods’ by the Town of Aurora Official Plan. The Stable Neighbourhoods designation permits the development of single detached dwellings subject to the development policies of the Official Plan. Zoning The subject lands are zoned R3-SN (497) (Detached Third Density Residential Exception Zone) by the Town of Aurora Zoning By-law #6000-17, as amended, where Detached Dwelling is listed as a permitted use. Page 33 of 62 October 10, 2024 3 of 10 Report No. MV-2024-27 Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town of Aurora’s Building Division. The PZR identified the required variances, and no other non-compliance was identified. Applicant’s stated reason(s) for not complying with the Zoning By-law The applicant has indicated that the dwelling footprint was determined based on project requirements provided by the client, which maintains a reduced footprint when comparing to the adjacent neighbour on the east. The applicant submits that the proposal has been designed in a manner that is intended to maintain the character of the landscape whil e also mitigating potential impacts to the streetscape by maintaining the required setbacks and height restrictions. Planning Comments Planning Staff have evaluated Minor Variance Application MV-2024-27 pursuant to the prescribed tests as set out in Section 45 (1) of the Planning Act, as follows: a) The proposed variance meets the general intent of the Official Plan The subject lands are designated ‘Stable Neighbourhoods’ under the Town of Aurora’s Official Plan. The intent of the ‘Stable Neighbourhoods’ designation is to ensure that all new development will be protected from incompatible forms of development. The designation permits ground-oriented residential development, which includes detached dwellings, and focuses on ensuring new development is designed in an appropriate and highquality manner to enhance the streetscape. The underlying priority is for new development and infill housing opportunities to be introduced in a complementary manner, particularly from an architectural design and compatibility perspective. To assist infill developments to be compatible with the exiting neighbourhood, a Stable Neighbourhood Design Guidelines was developed. The proposed dwelling has been reviewed with guidance from the Stable Neighbourhoods Design Guidelines. Staff are of the opinion that the requested variances will enhance the local streetscape by providing transition in design, size and massing from an adjacent two-storey detached dwelling to the east, and existing one-storey detached dwellings towards the west along Kennedy Street East. Page 34 of 62 October 10, 2024 4 of 10 Report No. MV-2024-27 Staff are of the opinion that the proposed development will enhance the attractivene ss of the streetscape and therefore meets the applicable policies and maintains the general intent and purpose of the Official Plan. b) The proposed variance meets the general intent of the Zoning By-law Maximum Gross Floor Area and Maximum Building Footprint The intent of regulating Gross Floor Area (GFA) and Maximum Building Footprint for residential dwellings is to ensure that properties are not overdeveloped relative to their lot area. As previously mentioned, the subject lot area is approximately 1,062.8 m2, which significantly exceeds the required lot area minimum of 460 m2 the R3-SN (497) zone. The applicant is proposing a total GFA of 452.5 m2 whereas a maximum of 370 m2 is permitted and a building footprint of 254 m2 whereas a maximum of 235 m2 is permitted. While the proposed detached dwelling exceeds the maximum GFA and building footprint provisions, all provisions pertaining to setbacks are maintained. The exceedance of the maximum GFA and Building Footprint provisions is a function of the proposed depth of the dwelling, and as such, there will be minimal impact towards the streetscape of Kennedy Street E. Ample space for outdoor amenity area is maintained at the rear of the property and sufficient space for pedestrian access and drainage is maintained from all property lines. Furthermore, the neighbouring detached dwelling immediately to the east (73 Kennedy Street E) is both larger and deeper than the proposed dwelling at hand. The subject variances will facilitate a detached dwelling that will provide a gradual decrease in size to transition from the neighbouring dwelling to longer-standing single storey dwellings along Kennedy Street E. Integral Garage to be Flush with, or Set Back from, the Main Front Wall The intent of requiring the integral garage to be flush with or set back from the main front wall of a dwelling is to maintain consistent streetscape by ensuring that the main wall of the dwelling is not overwhelmingly dominated by garage doors. While the integral garage projects approximately 1.2 m out of the main front wall of the dwelling, it is in line with the proposed front porch. Furthermore, a consistent roofline is proposed from the garage which extends and covers the front porch. This architectural feature minimizes the garage projection from the streetscape and presents more flush appearance along the front of the dwelling. It is Staff’s opinion that the requested variance to facilitate a projection of the integral garage from the main wall of the proposed detached dwelling maintains the intent of the Zoning By-law. Page 35 of 62 October 10, 2024 5 of 10 Report No. MV-2024-27 Accessory Detached Structure Gross Floor Area The intent of regulating the GFA of detached structures is to ensure that accessory structures truly appear and function secondary to the main str ucture, and to ensure that sufficient space is maintained on the property for drainage, access, and amenity area. The proposed accessory structure is to be utilized as a pool house/cabana which will complement the proposed in-ground pool in the rear yard. The proposed structure is one- storey and has a proposed GFA of 46.1 m2 whereas the By-law establishes a maximum GFA of 40 m2. The proposed structure will contain a changeroom, storage area, and a sauna. The accessory structure eave overhang is the attributing factor to the increase of the GFA. Given the previously referenced large nature of this lot, an increase of 6.1 m2 is minimal and maintains the intent of the zoning provision. Minimum Distance Separation from Pool to Buildings and Structures The applicant is requesting variances from the By-law to reduce the minimum distance separation from the proposed pool to the proposed accessory structure of 0.0 m and to the rear covered deck of 0.5 m whereas a minimum separation of 1.2 m is required. With respect to the 0.0 m separation from the accessory structure, this separation is calculated to the proposed overhang of the structure. The accessory structure is designed to have an extended overhang to serve as a covered patio area next to the proposed pool. The pool maintains an approximately 2.0 m setback from the closest wall of the accessory structure. Similarly, the 0.5 m separation from the pool to the rear covered deck is a function of an overhanging architectural feature projecting from the dwelling. An approximate 2.0 m separation from pool to the nearest wall of the dwelling is maintained. The intent of the structure is to ensure the structural integrity and pedestrian safety adjacent to swimming pools, and this intent is maintained, based on the 2.0 m setback from the pool to the nearest wall of the proposed accessory structure and the nearest wall of the proposed dwelling respectively. Based on the above, it is Staff’s opinion that the reduction of the pool setback from the proposed accessory structure of 0.0 m and to the proposed dwelling of 0.5 m maintains the intent of the Zoning By-law, as the setbacks are calculated to the closest overhanging features of buildings. The pool maintains setbacks of greater than 2.0 m from the closest wall of both buildings. Page 36 of 62 October 10, 2024 6 of 10 Report No. MV-2024-27 c) The proposed variance is considered desirable for the appropriate development of the land The minor variances have been considered in the context of the site itself and the adjacent neighbourhoods. The requested variances will enable the proposed dwelling to maintain ample amenity area while providing sufficient room for access and drainage. The dwelling is proportionate to the lot size and has been designed in a manner that respects privacy and spacing between buildings. The proposal allows for appropriate infill development while accommodating specific family housing and storage needs. It is the opinion of Staff that this is done so in a manner that respects the existing neighbourhood and streetscape and does not result in the overdevelopment of the lands. Furthermore, the proposed detached dwelling and accessory features serves as a transition in size and architectural design from newer detached dwellings to older existing detached dwellings along Kennedy Street E. As such, it is the opinion of Staff that the requested variances are considered desirable for the appropriate development of the land. d) The proposed variance is considered minor in nature In the opinion of the Staff, the requested variances are considered to be minor and are not expected to have any adverse impacts on the subject lands, neighbouring properties, or the character of the existing neighbourhood as a whole. The proposed development allows the property owner to maximize the large nature of the subject lot , while serving as a gradual transition in size and massing from the neighbouring two-storey dwelling to the east from the older one-storey dwellings west of the subject property. Staff are of the opinion that the increase in GFA and building footprint are numerically minor given the overall context and size of the site. This is reinforced by the fact that no setback variances to property lines have been requested as part of this proposal. Page 37 of 62 October 10, 2024 7 of 10 Report No. MV-2024-27 Additional Comments The minor variance application was circulated to Town Department/Divisions and to external agencies for review and comment. The following comments were provided: Department or Agency Comments Building Division Preliminary Zoning Review was completed. No objections. Engineering Division No objections. Operational Services (Parks) No objections. Operational Services (Public Works) No objections. Central York Fire Services No objections. York Region No objections. LSRCA No objections. Public Correspondence Written submissions were not received at the time of writing of this report. Should written submissions be received after the writing of this report, the Secretary Treasurer will provide the submission(s) to Committee members at the meeting. Conclusion Planning staff have reviewed the application with respect to the Section 45(1) of the Planning Act, R.S.O., 1990, c.P.13, as amended, and are of the opinion that the requested variances meet the four tests of the Planning Act for granting of minor variances. Staff recommend approval of the requested variance subject to the conditions outlined in Appendix ‘A’. Attachments Appendix ‘A’ – Recommended Conditions of Approval Page 38 of 62 October 10, 2024 8 of 10 Report No. MV-2024-27 Appendix ‘B’ – Site Plan Page 39 of 62 October 10, 2024 9 of 10 Report No. MV-2024-27 Appendix ‘A’ – Recommended Conditions of Approval The following conditions are required to be satisfied should MV-2024-27 be approved by the Committee of Adjustment: Planning and Development Services: 1. That the variance only applies to the subject property in conformity with the plan attached as ‘Appendix B’ to this Staff Report, to the satisfaction of the Director of Planning and Development Services or designate. 2. Prior to final approval of the minor variance, the Owner shall obtain a pre- construction inspection of the existing retaining wall by a qualified professional and provide a security deposit, as determined by the Town, to ensure a post- construction inspection is conducted. The security will be released only after the Town accepts the post-construction inspection report confirming the integrity of the retaining wall. Operational Services: 3. That the owner shall be required to provide an Evaluation Report prepared by a Certified Arborist or Professional Registered Forester outlining all aspects of the impacts that this proposal will have on existing trees. The report shall include the following: a. An assessment of existing trees (5cm trunk diameter and greater) by size, species and condition including trees on adjacent properties whose structure or root zone may be impacted by construction. b. Identification of all tree injuries and tree removals, if any. c. Identification of all tree protection measures including recommendations on the mitigation of negative effects to trees during and post construction, including applicable maintenance requirements. d. Provision of monitoring of the site work through a series of site visits by the Arborist/Forester to ensure protection/preservation measures remain in compliance throughout the duration of the project. Monitoring shall occur i) at commencement of work to certify all tree protection measures are in place, ii) during site work to confirm protection measures are in place and to oversee arboricultural works as required, and iii) post construction assessment. Each site visit is to be documented and any resulting action items required by the Arborist /Forester shall be implemented and confirmed on site forthwith by the Arborist /Forester following each visit. Page 40 of 62 October 10, 2024 10 of 10 Report No. MV-2024-27 e. A monetary evaluation in accordance with the Town’s Tree Compensation Policies for all trees designated to be removed. 4. The Owner shall be required to provide a tree compensation and a replanting plan in accordance with the Town of Aurora Tree Compensation Policies to the satisfaction of the Director of Operational Services as compensation for trees removed to facilitate construction. Compensation planting shall be completed prior to release of the financial securities. 5. The owner shall agree to comply with the Aurora Tree Permit By-law # 5850 -16 prior to the removal of any trees on the property. 6. The owner shall be required to provide financial securities based on the total value of the Tree Compensation evaluation and all Arboriculture works as defined by the Town and the Owner’s Arborist/ Forester, to the satisfaction of the Director of Operational Services. 7. All the above shall be included as terms and conditions in a Letter of Undertaking with the Town of Aurora to guarantee compliance with the Conditions of Approval and all related site works. Engineering & Capital Delivery Division 8. All roof drains are required to discharge onto splash pads on grassed areas. Residential roof leaders/downspouts shall not be connected to any sewers/drains. Given a flat roof is proposed for the house, drawings showing the roof leaders/downspouts locations demonstrating fulfilment of the above noted criteria is submitted to the satisfaction of the Director of Planning and Development Services or designate. Page 41 of 62 1.STEEL POSTS WHICH SUPPORT THE SILT FENCESHALL BE INSTALLED ON A SLIGHT ANGLETOWARD THE ANTICIPATED RUNOFF SOURCE.2.THE TOE OF THE SILT FENCE SHALL BETRENCHED IN WITH A SPADE OR MECHANICALTRENCHER, SO THAT THE DOWN SLOPE FACEOF THE TRENCH IS FLAT AND PERPENDICULARTO THE LINE OF FLOW.3.THE TRENCH SHOULD BE A MINIMUM OF SIXINCHES DEEP AND SIX INCHES WIDE TOALLOW FOR THE SILT FENCE TO BE LAID IN THEGROUND AND BACKFILLED.4.SILT FENCE SHOULD BE SECURELY FASTENEDTO EACH SUPPORT POST.5.INSPECTION SHALL BE FREQUENT AND REPAIROR REPLACEMENT SHALL BE MADE PROMPTLYAS NEEDED.6.SILT FENCE SHALL BE REMOVED WHEN IT HASSERVED ITS USEFULNESS, SO AS NOT TOBLOCK OR IMPEDE STORM FLOW ORDRAINAGE.7.SEDIMENT TRAPPED BY THIS PRACTICE SHALLBE DISPOSED OF IN AN APPROVED SITE IN AMANNER THAT WILL NOT CONTRIBUTE TOADDITIONAL SILTATION.8.ACCUMULATED SILT SHALL BE REMOVEDWHEN IT REACHES A DEPTH OF SIX INCHESAND DISPOSED OF IN AN APPROVED SPOILSITE OR AS IN NO. 7 ABOVE.9.FILTER FABRIC IS TO BE VERIFIED BY THEMUNICIPALITY PRIOR TO INSTALL.10.CONTRACTOR TO REMOVE SILT FENCE UPONCOMPLETION OF PROJECT. DAMAGED AREAS TO BE REPAIRED INCLUDING RE-GRADING ANDRE-GRASSING AS NECESSARY.11.ALL EROSION CONTROL DEVICES ANDREQUIREMENTS SHALL BE IN ACCORDANCEWITH THE PROVISIONS OF THE MUNICIPALITYAND SHALL SUPERCEDE THE DETAILS HEREWITHIN IF THERE ARE ANY DISCREPANCIES.12.UNLESS APPROVED BY OWNER, EROSIONCONTROL FENCING SHALL BE USED IN AREASWITH NO TREES ONLY.STEEL 'T' BAR POSTFILTER FABRICCOMPACTED NATIVE SOILBACKFILLFASTEN FABRIC WITH WIRE TIESMIN. SETBACK FROMPROPERTY LINE6"6"STEEL 'T' BAR POSTS [2" X 2" X 36"] SPACED@ 8'-0" O.C.6" WIRE FENCINGATTACHED TO POSTSWOVEN GEOTEXTILE LANDSCAPE CLOTHFOLDED OVER AND WIRE LOOPED TO FENCE8'-0" O.C.2'-0"XIB(OU)XOH OHIB(1345)CC(WIT)(1345)IB(OU)IB(OU)IB(OU)IB(OU)IB(OU)XXBF CLFPWF DBFDBF CLF CLF CLFGATE OHOHOHOH1.656.951.501.503.191.631.2236.49 1.191.205.55 2.502 STOREY SINGLE FAMILYDWELLINGPROPOSEDASPHALT DRIVEWAYPROPOSED POOLPROPOSEDCABANA3.066.9523.57 2.005.995.724'-0" FROM DECK 6'-6"DECK ABOVEC:\Users\jsher\Downloads\JUST[IN] _Logo_Full.png[ SP ]JUSTIN SHERRY DESIGN STUDIO17 POYNTZ STREET, BARRIE, ONTARIOL4M 3N6INFO@JUSTINSHERRY.CA [705] 300 2341WT[ ][ ]GENERAL NOTES[1]DRAWINGS ARE TO BE READ NOT SCALED.[2]DO NOT BEGIN CONSTRUCTIONUNTIL DESIGNER OR PROJECTMANAGER HAS BEEN NOTIFIED.[3]UPON COMPLETION OF ANY STAGEOF CONSTRUCTION, THE DESIGNEROR PROJECT MANAGER SHALL BENOTIFIED TO ENSURE PROPERINSPECTION.[4]ALL DESIGN AND CONSTRUCTIONDOCUMENTATION ARE FINAL UNLESSREVISED BY THE DESIGNER.[5] IF ANY DISCREPANCIES AREDISCOVERED HERE WITHIN, THEDESIGNER SHALL BE NOTIFIED.[6]THE DRAWINGS AND DOCUMENTSPROVIDED HERE WITHIN ARE THEEXCLUSIVE PROPERTY OF JUSTINSHERRY DESIGN STUDIO.REPRODUCTION OF THE DOCUMENTSPROVIDED IS PROHIBITED WITHOUTTHE CONSENT OF THE DESIGNER.ENGINEER'S SEALN.T.S.[ SCALE ][ CHECKED BY ][ DRAWN BY ][ PAGE NO. ]SITE PLAN[PROJECT NO.][ SITE PLAN ] [ TRUE NORTH ] [ PROJECT NORTH ]REVISIONSMM.DD.YYYY[ 1 ] -ISSUE DATE08.06.2024[ 1 ] ISSUED FOR REVIEW69 KENNEDY STREET EASTAURORA, ONTARIOJUSTIN SHERRYJUSTIN SHERRY2024-035C:\Users\jsher\Downloads\Justin Sherry Signature.jpgQUALIFICATION INFORMATIONTHE UNDERSIGNED HAS REVIEWED ANDTAKES RESPONSIBILITY FOR THIS DESIGN,AS WELL AS HAVING THE QUALIFICATIONAND REQUIREMENTS MANDATED BY THEONTARIO BUILDING CODE TO BE ADESIGNER.[ B.C.I.N. ][ SIGNATURE ]43529JUSTIN SHERRYREGISTRATION INFORMATIONREQUIRED UNLESS THE DESIGN IS EXEMPTUNDER DIVISION -3.2.4. OF THE ONTARIOBUILDING CODE[ B.C.I.N. ][ FIRM NAME ]124208JUSTIN SHERRY DESIGN STUDIOSCALE: 1/16" = 1'-0"[ SILT FENCING DETAIL ][ ZONING LEGEND ]ADDRESS:69 KENNEDY ROADZONING:R3-SN (497)STANDARDSPERMITTEDPROVIDEDLOT AREA [ MIN. ]LOT FRONTAGE [ MIN. ]FRONT YARD SETBACK [ MIN. ]SIDE YARD SETBACK [ MIN. ]SIDE YARD SETBACK ONE SIDE [ MIN. ]EXTERIOR SIDE YARD SETBACK [ MIN. ]REAR YARD SETBACK [ MIN. ]LOT COVERAGE [ MAX. ]BUILDING HEIGHT [ MAX. ]460.00 M21061.41 SQ. M.15.00 M15.85 M.1.50 M/3.00 M1.50 M. / 3.06 M.1.50 M.1.63 M.25.00%36.49 M. (54.43%)9.00 M.8.70 M.[ DWELLING REQUIREMENTS ]ADDITIONAL REQUIREMENTS [ IF ANY ]:[ SITE PLAN NOTES ]1.NO DRAINAGE ONTO ADJACENTPROPERTIES.2.ENCHROCHMENTS: NO ENCROACHMENTS PERMITTEDONTO ADJACENT PROPERTIESABOVE OF BELOW GRADEINCLUDING EAVES, OVERHANGSAND FOOTINGS.3.SURFACE DRAINAGE SHALL NOT BEDISCHARGED DIRECTLY ORINDIRECTLY ONTO A SIDEWALKDRIVEWAY, STAIRWAY OR ANADJOINING PROPERTY.4.NO WORK TO ENCROACH ONTOADJOINING PROPERTIES6.00 M6.95 M.N.A.35.00% OR 235.00 SQ. M.BUILDING: 254.31 M26.00 MGROSS FLOOR AREA MAX. INCL. OF GARAGE370.00 SQ. M.GROUND: 178.11 SQ. M.GARAGE: 67.39 SQ. M.SECOND: 200.75 SQ. M.TOTAL: 446.25 SQ. M.CABANA: 31.74 M2286.05 M2 (26.95%)PR20241058Sept. 17, 2024TOWN OF AURORA PLANNING & DEVELOPMENT SERVICES BUILDING DIVISIONPERMIT NO.: DATE:PRELIMINARY ZONING REVIEWAPPROVED BY: Taylor ColePage 42 of 62 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 4 -28 _______________________________________________________________________________________ Subject: Minor Variance Application Andrew Risk 15 Tyler Street PLAN 9 PT LOTS 7 AND 8 AND RP 65R25427 PART 1 File: MV-2024-28 Prepared by: Antonio Greco, Senior Planner Department: Planning and Development Services Date: October 10, 2024 _______________________________________________________________________________________ Application The applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to facilitate the construction of a five-storey mixed use building with at grade office and residential above. The vehicular access is off Temperance Street with parking at rear. The following relief is being requested: a) Section 8.2 of Zoning By-law 6000-17 permits a maximum height of 10 meters. The applicant is proposing a five-storey residential building containing a maximum height of 20 metres. b) Section 5.4 of Zoning By-law 6000-17 requires parking for offices at a rate of 3.5 spaces per 100 square meters of Gross Floor Area and 1.5 spaces per dwelling unit, with a minimum 20% of spaces provided to be set aside for visitor parking. Therefore 10 parking spaces inclusive of a barrier free parking space is required. The applicant is proposing a total of seven (7) parking spaces inclusive of the barrier free space. Background Subject Property and Area Context The subject property is located at the southeast corner of Temperance Street and Tyler Street, approximately 87 m (285 ft) west of Yonge Street. The subject property has an Page 43 of 62 October 10, 2024 2 of 10 Report No. MV-2024-28 area of roughly 399.22 m2 (4297.16 ft2) and a frontage of approximately 12.66 m (41.53 ft) on Tyler Street and 31.76 m (104.19 ft) on Temperance Street. The subject property contains a one-storey detached dwelling, which is currently listed on the Town of Aurora Register of Properties of Cultural Heritage Value or Interest. Proposal The applicant is proposing to demolish the existing one-storey detached dwelling on the subject property and facilitate the construction of a five-storey mixed use building, containing office on the ground floor with residential rental units above. Official Plan The subject property is designated within the “Aurora Promenade and MTSA Mixed Use” on Schedule ‘B’ – Land Use Plan by the Town of Aurora Official Plan and specifically designated as “Downtown” within Schedule ‘D1’ - The Aurora Promenade and Major Transit Station Area Secondary Plan Area. This designation is intended to accommodate a mixture of uses such as dwelling units located on the second storey, and/or above all building types and commercial/institutional uses. Zoning The Subject property is zoned “PD1 – Promenade Downtown” under Zoning By-law 6000- 17, as amended. This zoning permits for a wide range of uses, including dwelling units above the first storey and a variety of commercial, retail and institutional uses. Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town of Aurora’s Building Division. The PZR identified the required variances, and no other non-compliance was identified. Applicant’s stated reason(s) for not complying with the Zoning By-law As stated in the application form, “the applicant seeks to provide rental units with the increased maximum height of the proposed building.” Planning Comments Planning staff have evaluated Minor Variance Application MV-2024-28 pursuant to the prescribed tests as set out in Section 45 (1) of the Planning Act, as follows: Page 44 of 62 October 10, 2024 3 of 10 Report No. MV-2024-28 a) The proposed variance meets the general intent of the Official Plan The subject property is designated “Downtown” by the Town of Aurora Official Plan. This designation is intended to guide development, while protecting and reinforcing a heritage ‘main street’ character and identity. The careful regulation of land uses and control over the scale and placement of infill structures is required to enhance the pedestrian experience, while still allowing for and promoting increased density in keeping with the character and scale of the Downtown. A mixture of uses is encouraged not just within this designation in general, but also on individual development sites, and within individual buildings. As mentioned previously, the existing one-storey dwelling is currently a listed property on the Heritage Registry. As part of the application circulation, a preliminary review was conducted on the building’s cultural heritage significance, which demonstrated a minimal value. That said, a condition of approval has been developed that requires the owner/applicant to obtain the necessary clearance from Town of Aurora Council to remove (delist) the property from the Town's Heritage Registry. Consultation will also be required to occur with the Town's Heritage Advisory Committee (HAC), with the submission of a Cultural Heritage Evaluation Report demonstrating support. Furthermore, properties within the Aurora Promenade and Major Transit Station Area contain specific minimum and maximum building heights. The subject property permits a maximum of five (5) storeys as per Schedule D-2 of the Official Plan. The proposed construction of a five-storey mixed use building and rear yard parking lot complies with the permitted uses, development policies and the building height provisions of the Official Plan. Development within the Aurora Promenade is to accommodate a broad range of choices for travel. Yonge Street and Wellington Street will accommodate transit, cyclists, pedestrians, as well as cars through a complete streets approach. Overall, Staff are therefore of the opinion that the proposed variances meet the general intent of the Official Plan. b) The proposed variance meets the general intent of the Zoning By-law The Subject property is zoned “Promenade Downtown (PD1)” under Zoning By-law 6000- 17, as amended. The intent of this zoning is to provide a wide variety of residential, commercial and institutional uses, while focusing on growth and intensified development, accommodating the highest densities within Aurora. A summary of the variances requested and how they meet the general intent of the zoning is as follows: Page 45 of 62 October 10, 2024 4 of 10 Report No. MV-2024-28 Maximum Building Height: The intent of the building height provision is to ensure that development is designed in a consistent manner with no singular buildings negatively impacting or dominating the downtown streetscape. The uniform pattern along the Aurora Promenade is to provide an attractive streetscape while maximizing the potential of individual residential lots. The Official Plan and Zoning By-law function concurrently to ensure the appropriate development of specific areas and individual lots in Town. As mentioned earlier in this report, the proposed building height is in line with the provisions of the Official Plan and the “Downtown” designation, which allows for a minimum of two (2) storeys and a maximum of five (5) storeys. The Town has commenced the comprehensive review of the Zoning By-law, which will review and update areas in Town that don’t align amongst both policy documents. The Aurora Promenade and Major Transit Station Area is an identified area that requires review of the baseline maximum height provisions. Furthermore, the proposed minor variance to increase the maximum height is required, as the Town’s Comprehensive Zoning By-law 6000-17 currently reflects a base line maximum of 10 metres and has not been updated to align its current standards to what is currently permitted from an Official Plan standpoint. Section 8.2 of the Zoning By-law provides a breakdown of the maximum heights within the Promenade Zones. There is an exception in the PD1 Zone that permits for a maximum height of 18.5 metres, provided the 4th and 5th storeys are setback a minimum of 3 m from the main and exterior side walls of the 3rd storey. When taking this into consideration, the increase from 18.5 metres to 20 metres is minor and meets the intent of the Zoning By-law. In addition, when evaluating the maximum height for apartment buildings, there is always a height range between 3.0 metres to 4.0 metres per storey. This range is dependent of whether there are residential or retail units of the ground floor, which can provide a range of ceiling heights between 8 feet to 10 feet and whether residential units above the ground floor are providing lofts. Given this 3.0 metres to 4.0 metres per storey range, a five-storey building can be anywhere from 15 metres to 20 metres. Even at its absolute lowest, a minor variance application would have been required. Provided all this information, Staff are of the opinion that the proposed maximum height continues to meet the general intent of the Zoning By-law and provides an attractive rental housing product to the neighbourhood. Minimum Parking: The intent of the minimum parking space requirement is to ensure that sufficient parking spaces are provided to meet the needs of the proposed residential building, and that vehicle spillover will not occur for overcrowding of the subject site. The proposed Page 46 of 62 October 10, 2024 5 of 10 Report No. MV-2024-28 development requires a total of ten (10) parking spaces, which accounts for the office use, residential use, visitor parking and barrier free parking. That said, the applicant is proposing a total of seven (7) parking spaces , which in the opinion of Staff is sufficient for the proposed development. The current parking supply will provide for at least one space per residential unit, which is now the standard for any residential development within a downtown core. The proposed office on the ground floor is to function as a live-work unit, only open to the private residents of the building, therefore, not creating any additional public traffic onsite. When taking that into consideration that there are areas currently within the Aurora Promenade that requires only one space per unit, inclusive of visitor parking spaces, the proposed seven (7) parking spaces is sufficient to accommodate the residential development. Residential projects within a downtown core are focused on transit-orientated development and to prioritize intensification within the Secondary Plan area as the Town’s primary location for growth and density, reinforcing the importance of the Aurora GO Station as a Major Transit Station area. Furthermore, when the applicant originally presented the minor variance application, a variance pertaining to the minimum distance separation for the barrier free parking space was also required. However, after further consultation with Staff and design changes to the building, the applicant was able to accommodate the barrier free parking space and its appropriate standard to eliminate the need for the additional variance. Given this change, the minor variance application only requires two variances versus the original three. The proposed seven (7) parking spaces meets the general intent of the Zoning By-law and is sufficient for the future development of the subject property. c) The proposed variance is considered desirable for the appropriate development of the land As discussed above, Staff are satisfied the proposal adequately responds to the newly adopted Town of Aurora Official Plan 2024, and the criteria for new development within the Aurora Promenade and Major Transit Station Area. The proposed development will also provide critical new and attainable housing opportunities for the local community. The proposed infill residential development enhances the urban design of the neighbourhood by providing the wise use and management of land within the Aurora Promenade. In addition, the proposed development will promote a truly mixed residential community that houses people of different ages, backgrounds, lifestyles and economic status. The Promenade is envisioned to function as a vibrant, mixed-use, pedestrian oriented community with a range and mix of housing options and densities and access to higher order transit. Page 47 of 62 October 10, 2024 6 of 10 Report No. MV-2024-28 Primarily though, the need for new, diverse, and attainable housing is paramount and the ability for the proposed development to add rental housing units to the Aurora Promenade is of benefit to current and future generations in addressing various housing needs. The proposed intensification of an underutilized lot aligns with the direction of the Province under Bill 23. The increase in building height and reduced parking standards will not negatively impact the surrounding area but enhance the overall function of the subject property and align with the vision of development with the Aurora Promenade. Lake Simcoe Region Conservation Authority has reviewed the application and confirmed that based on the information submitted as part of this minor variance application, the proposal is located outside of the flood hazard and is therefore consistent with 3.1 of the Provincial Policy Statement (PPS). The appropriate condition s of approval have been implemented, requiring the applicant to obtain a permit from the LSRCA prior to development or site alteration. Overall, it is the opinion of Staff that the proposed variances are considered desirable for the appropriate development of the land. d) The proposed variance is considered minor in nature In the opinion of staff, the requested variances are considered to be minor in nature and are not expected to have any significant adverse effects on the subject property, neighbouring properties, or the overall streetscape. The proposed development is designed to implement the building height policies of Official Plan and the Aurora Promenade and Major Transit Station Secondary Plan Area. The proposed increase in maximum height from a numerical value is double but does not accurately depict what can be done on the property as of right. Furthermore, the reduction in parking can adequately serve the proposed residential development without negatively impacting surrounding properties. The proposal introduces new and attainable rental housing opportunities in a manner that still respects the overall neighbourhood character and scale. The appropriate conditions of approval have also been developed, including for the need to obtain a Road Occupancy Permit, and to ensure any tree removals are evaluated through an evaluation report completed by a certified professional. The Town’s Engineering Department have also reviewed the proposed minor variance application and have no comments as it pertains to the proposed development. Overall, it is the opinion of Staff that the proposed variances are minor in nature. Page 48 of 62 October 10, 2024 7 of 10 Report No. MV-2024-28 Additional Comments The minor variance application was circulated to Town Department/Divisions and to external agencies for review and comment. The following comments were provided: Department or Agency Comments Building Division Preliminary Zoning Review completed. No objection. Engineering Division No objection. Operational Services (Parks) No objection. Operations (Public Works) No objection. Central York Fire Services No objection. York Region No objection. LSRCA No objection. Alectra No objection. Public Correspondence At the time of writing this report, two written submissions in opposition were received. If additional written submissions are received after the writing of this report, the Secretary- Treasurer will provide the submission(s) to Committee members at the meeting. Conclusion Planning staff have reviewed the application regarding Section 45 (1) of the Planning Act, R.S.O, 1990, c.P.13, as amended, and believe that the requested variance meets the four tests of the Planning Act for granting minor variances. Staff recommend approval of the requested variance subject to the condition outlined in Appendix ‘A. Attachments Appendix ‘A’ – Recommended Conditions of Approval Appendix ‘B’ – Site Plan & Elevations Page 49 of 62 October 10, 2024 8 of 10 Report No. MV-2024-28 Appendix ‘C’ – Floor Plans & Elevations Appendix ‘A’ – Conditions of Approval Planning and Development Services: 1. That the variance only applies to the subject property in conformity with the plans attached as ‘Appendix B’ to this Staff Report, to the satisfaction of the Director of Planning and Development Services or designate. 2. That the owner obtains necessary clearance from Town of Aurora Council to remove (delist) the property from the Town's Heritage Register. Consultation will also be required to occur with the Town's Heritage Advisory Committee (HAC), and the submission of a Cultural Heritage Evaluation Report will be required demonstrating support. Operational Services – Parks Division: 3. That the owner shall be required to provide an Evaluation Report prepared by a Certified Arborist or Professional Registered Forester outlining all aspects of the impacts that this proposal will have on existing trees. The report shall include the following: a. An assessment of existing trees (5cm trunk diameter and greater) by size, species and condition including trees on adjacent properties whose structure or root zone may be impacted by construction. b. Identification of all tree injuries and tree removals, if any. c. Identification of all tree protection measures including recommendations on the mitigation of negative effects to trees during and post construction, including applicable maintenance requirements. d. Provision of monitoring of the site work through a series of site visits by the Arborist/Forester to ensure protection/preservation measures remain in compliance throughout the duration of the project. Monitoring shall occur i) at commencement of work to certify all tree protection measures are in place, ii) during site work to confirm protection measures are in place and to oversee arboriculture works as required, and iii) post construction assessment. Each site visit is to be documented, and any resulting action Page 50 of 62 October 10, 2024 9 of 10 Report No. MV-2024-28 items required by the Arborist /Forester shall be implemented and confirmed on site forthwith by the Arborist /Forester following each visit. e. A monetary evaluation in accordance with the Town’s Tree Compensation Policies for all trees designated to be removed. 4. The Owner shall be required to provide a tree compensation and a replanting plan in accordance with the Town of Aurora Tree Compensation Policies to the satisfaction of the Director of Operational Services as compensation for trees removed to facilitate construction. Compensation planting shall be completed prior to release of the financial securities. 5. The owner shall agree to comply with the Aurora Tree Permit By-law # 5850 -16 prior to the removal of any trees on the property. 6. The owner shall be required to provide financial securities based on the total value of the Tree Compensation evaluation and all Arboriculture works as defined by the Town and the Owner’s Arborist/ Forester, to the satisfaction of the Director of Operational Services. 7. All the above shall be included as terms and conditions in a Letter of Undertaking with the Town of Aurora to guarantee compliance with the Conditions of Approval and all related site works. Operational Services – Public Works: 8. That the Owner obtain a Road Occupancy Permit through Public Works. 9. That the Owner be required to CCTV the existing sanitary to see if it can be used for this proposed development. The developer will also be required to confirm the size of the water service. Engineering and Capital Delivery – Engineering Department: 10. Prior to final approval of the minor variance, the owner shall obtain final approval for a daylight triangle at the intersection of Temperance Street and Tyler Street and driveway to the satisfaction of the Town’s planning and development services Lake Simcoe Region Conservation Authority: 11. That the Applicant/Owner shall pay the LSRCA Plan Review Fee in accordance with the approved LSRCA Fee Schedule. The applicable fee for Minor Variance (Minor – planner review only) is $536.00. Page 51 of 62 October 10, 2024 10 of 10 Report No. MV-2024-28 12. That the Applicant/Owner successfully obtain a permit from the LSRCA prior to development or site alteration. York Region: 13. A Section 59 applies at the minor variance stage and needs to be completed prior to approval. Please have the applicant submit Section 59 - Planning Application Form. 14. Prior to final approval of the application, the Town of Aurora shall confirm that adequate water supply and sewage capacity has been allocated for the proposed dwellings. Page 52 of 62 31.76 12.66 31.76 12.66 P11.275.30 BOREHOLE LOCATIONUSFUNDERSIDE FOOTING ELEVATIONTFWFBSFFLGHS W 1 0 0 . 0 0100.00HWENGINEERED FILL LOTDOWNSPOUT LOCATIONTELECOM. JUNCTION BOXFINISHED FLOOR ELEVATIONTOP OF FOUNDATION WALLFIN. BASEMENT FLOOR SLABGAS METERPROPOSED BERMSWALE DIRECTIONHYDRO METERSANITARY MANHOLEVALVE AND CHAMBERAIR-CONDITIONING UNIT PROPOSED SWALE GRADEEXISTING GRADEPROPOSED GRADESTORM MANHOLESTREET LIGHTCABLE TV PEDESTALCOMMUNITY MAILBOXENTRANCE DOOR LOCATIONGARAGE DOOR LOCATIONBELL PEDESTALHYDRANTTRANSFORMERSTORM CONNECTIONHYDRO CONNECTIONDOUBLE CATCH BASINWATER CONNECTIONSANITARY CONNECTIONCATCH BASINMAILLEGENDBH 1AA'SLOPE SECTIONRRECYCLING BINGGARBAGE BINDISTANCES SHOWN ON THIS PLAN AREIN METRES AND CAN BE CONVERTEDTO FEET BY DIVIDING BY 0.3048.METRICSITE STATS(m)EASTWEST20SPATIAL SEPARATION-CONSTRUCTION OF EXTERIOR WALLSWALLAREAOF EBFL.D.L/HORH/LPERMITTEDMAX.% OFOPENINGSPROPOSED% OFOPENINGSFRR(HOURS)LISTED DESIGNOR DESCRIPTIONCOMB.CONSTCOMB.CONSTR./NON-COMB.CLADDINGONTARIO BUILDING CODE DATA MATRIXITEMOBC REFERENCE PART 3PART 9 PART 11 NEW ADDITION ALTERATION CHANGE OF USEPROJECT DESCRIPTION:12345678910111213141516171819MAJOR OCCUPANCY(S)BUILDING AREA (m )GROSS AREA (m )NUMBER OF STOREYS ABOVE GRADE___ BELOW GRADE___HEIGHT OF BUILDING (m)NUMBER OF STREETS/ACCESS ROUTESBUILDING CLASSIFICATIONSPRINKLER SYSTEM PROPOSED ENTIRE BUILDING BASEMENT ONLY IN LIEU OF ROOF RATING NOT REQUIRED NO YESSTANDPIPE REQUIREDFIRE ALARM REQUIREDWATER SERVICE/ SUPPLY IS ADEQUATEHIGH BUILDINGPERMITTED CONSTRUCTIONACTUAL CONSTRUCTION COMBUSTIBLE COMBUSTIBLE NON-COMBUSTIBLE NON-COMBUSTIBLEBOTHBOTHMEZZANINE(S) AREA m DESIGN OF BUILDING m /PERSONOCCUPANT LOAD BASED ONBASEMENT:1st FLOOR2nd/3rd FLOOR4th FLOOROCCUPANCY________ LOAD________ PERSONSOCCUPANCY________ LOAD________ PERSONSOCCUPANCY________ LOAD________ PERSONSOCCUPANCY________ LOAD________ PERSONS YES YES NO NOLISTED DESIGN NO. ORDESCRIPTION (SG-2)HORIZONTAL ASSEMBLIESFRR (HOURS)REQUIRED FIRERESISTANCERATING (FRR)FLOORS ______HOURSROOFS ______HOURSMEZZANINE______HOURSFRR OF SUPPORTING MEMBERSBARRIER-FREE DESIGNHAZARDOUS SUBSTANCESFLOORS ______HOURSROOFS ______HOURSMEZZANINE______HOURS YES YES YES NO NO NOCOMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey, structural,mechanical, electrical, etc. engineering information shown on the drawing. Refer to theappropriate engineering drawings before proceeding with work.Contractor shall check all dimensions on the work and report any discrepancy to theArchitectural Technologist before proceeding. Construction must conform to all applicableCodes and Requirement of Authorities having Jurisdiction.All drawings, specifications and related documents are the copyright property of Peter DelGrosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNSITE PLANSP-01PROPOSED 4 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 24/241:200PDG00-001.DEC. 9/23ISSUED FOR REVIEW2.SEPT. 16/24REV. BARRIER-FREE PARKING3.OCT. 1/24REDUCED FRONT YOARD SETBACK4.5.6.7.8.P2P311.046.60 2.703.655.300.263.65 P4P5P6P70.141.50 Page 53 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNEXISTING GROUND FLOOR PLANA-01PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 54 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED SECOND/THIRD FLOORA-02PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 JULY 27, 2024Page 55 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED FORTH GROUND FLOORA-03PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.BRASSFAUCETMARGAUXK-16232-4 GASFIREPLACE JULY 27, 2024Page 56 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED MEZZANINE FLOORA-04PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.BRASSFAUCETMARGAUXK-16232-4 BRASSFAUCETMARGAUXK-16232-4 JULY 27, 2024Page 57 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNPROPOSED ROOF TOP PATIOA-05PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 58 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNNORTH (FRONT) ELEVATIONA-06PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 59 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNWEST (SIDE) ELEVATIONA-07PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 60 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNEAST (SIDE) ELEVATIONA-08PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 61 of 62 COMPLIANCE PACKAGE "A1"The Architectural Technologist is not responsible for the accuracy of survey,structural, mechanical, electrical, etc. engineering information shown on thedrawing. Refer to the appropriate engineering drawings before proceedingwith work.Contractor shall check all dimensions on the work and report anydiscrepancy to the Architectural Technologist before proceeding.Construction must conform to all applicable Codes and Requirement ofAuthorities having Jurisdiction.All drawings, specifications and related documents are the copyrightproperty of Peter Del Grosso O/A 2493572 Ontario Inc. and must bereturned upon request. Reproduction of drawings, specificationsand related documents in part or whole is forbidden withoutthe permission of Peter Del Grosso.This drawing is not to be scaled.This drawing is not to be used for construction unless signed bythe Architectural Technologist.DRAWING TITLE:The undersigned has reviewed and takes responsibility for thisdesign, and has the qualifications and meets the requirements setout in the Ontario Building Code to design the work shown on theattached documentsQUALIFICATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.5 of The Building CodePETER DEL GROSSO 20567REGISTRATION INFORMATIONRequired unless design is exempt underDivision C, Subsection 3.2.4 of The Building CodePETER DEL GROSSO 27288PROJECT No.:NO: DATE:REVISION:PROJECT:4370 Steeles Avenue West,Suite 203Woodbridge, Ontario L4L 4Y4T: 416 453 9985e-mail: peterd@pdeldesign.cawww.pdeldesign.caP DEL DESIGNSOUTH (REAR) ELEVATIONA-09PROPOSED 5 STOREY BUILDING15 TYLER STREETAURORA, ONTARIOJULY 26/243/16"=1'-0"PDG00-001.AUG. 26/24ISSUED FOR REVIEW2.OCT. 1/24REV. TILE BLOCK TO 5 STOREY BUILDING3.4.5.6.7.8.JULY 27, 2024Page 62 of 62