Loading...
Agenda - Committee of Adjustment - 20221013Town of Aurora Committee of Adjustment Meeting Agenda Date:Thursday, October 13, 2022 Time:7:00 p.m. Location:Video Conference Aurora Council and Committee meetings are live streamed on the Town’s YouTube Channel. For information on how to participate in this meeting please visit aurora.ca/participation. Pages 1.Call to Order 2.Land Acknowledgement 3.Approval of the Agenda That the Agenda as circulated by the Secretary-Treasurer be approved. 4.Declarations of Pecuniary Interest and General Nature Thereof 5.Receipt of the Minutes 5.1.Committee of Adjustment Meeting Minutes of September 8, 2022, Meeting Number 22-09 That the Committee of Adjustment Minutes from Meeting Number 22-09 be adopted as circulated. 6.Presentation of Applications 6.1.MV-2022-35 - Dunn - 174 Corner Ridge Rd 1 6.2.MV-2022-36 - Rallis - 12 Buchanan Cres 9 7.New Business 8.Adjournment 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 2 -35 _______________________________________________________________________________________ Subject: Minor Variance Application Dunn 174 Corner Ridge Road Lot 23 PLAN 65M-2748 File: Insert File # MV-2022-35 Prepared by: Rosanna Punit, Planner Department: Planning and Development Services Date: October 13, 2022 _______________________________________________________________________________________ Application The owner/applicant is requesting relief from the requirements of the Town’s Comprehensive Zoning By-law 6000-17, as amended, to permit an inground pool with a decreased side yard setbacks. The following relief is being requested: a) Section 4.12 of the Zoning By-law requires inground pools shall be setback a minimum of 1.2m from the rear and side lot lines. The applicant is proposing an inground pool, which is 0.9m to the side lot line. Background Subject Property and Area Context The subject property, municipally known as 174 Corner Ridge Road, is generally located south of Wellington and east of Bathurst Street. The subject property is an interior lot located on the south side of Corner Ridge Road. The subject property has a lot area of approximately 518m2 (5575ft2) and a lot frontage of approximately 15m (49ft). The street is an established residential neighbourhood that is generally characterized by two storey dwellings. To the rear of the property is a new subdivision that is currently under construction (Klees Cresent). Page 1 of 17 October 13, 2022 2 of 7 Report No. MV-2022-35 Proposal A pool enclosure permit application was applied for and issued by the Building Department. The inground pool proposed was shown to be in compliance with the Town’s Zoning By-law 6000-17, as amended on the pool enclosure permit. Upon final inspection, it was identified that the inground pool was built, not in compliance with the Town Zoning By-law, as amended. Official Plan The subject property is designated “Stable Neighbourhoods” by the Town of Aurora’s Official Plan, which seeks to ensure that residential neighbourhoods are protected from incompatible forms of development, while allowing the neighbourhoods to be enhanced over time. Zoning The subject property is zoned “R3(125)” (Detached Third Density Residential Exception 125 Zone) by Zoning By-law 6000-17, as amended, which permits single detached dwellings. Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town of Aurora’s Building Division. The PZR identified the required variance, and no other non-compliance was identified. Applicant’s stated reason(s) for not complying with the Zoning By-law As stated on the application form, “the pool has already gone in, and the fence is completed” Planning Comments Planning Staff have evaluated Minor Variance Application MV- 2022-35 pursuant to the prescribed tests as set out in Section 45(1) of the Planning Act, as follows: a) The proposed variance meets the general intent of the Official Plan The intent of the Official Plan Designation is to protect from incompatible forms of development and at the same time are permitted to evolve and be enhanced overtime. Staff are of the opinion that the intent of the Official Plan is being maintained. Page 2 of 17 October 13, 2022 3 of 7 Report No. MV-2022-35 b) The proposed variance meets the general intent of the Zoning By-law The side yard setback provision is to ensure appropriate and adequate spacing between buildings and lots. The Engineering Division, has identified that the site plan shows the built pool’s water edge encroaching approximately 0.286m into an existing 1.2m wide Town sewer easement. The neighbouring property to the west also has a 1.8m wide easement, which combined provides a 3.0m easement that allows the Town access to a rear yard catch basin and storm lead located on the adjacent property. The catch basin lead drains to Corner Ridge Road. Engineering Division staff are not aware of any drainage complaints because of the pool encroachment. Engineering staff have provided conditions should the minor variance application be approved by the Committee. Planning staff are of the opinion that the requested variance is in keeping with the general intent of the Zoning by-law, with the recommended conditions of Engineering staff. c) The proposed variance is considered desirable for the appropriate development of the land Staff are of the opinion that the pool encroachment is desirable for the development of the land, with the provided Engineering conditions, should the application be approved. d) The proposed variance is considered minor in nature Staff are of the opinion that the pool encroachment is minor in nature and has minimal impacts to the existing neighbourhood streetscape. Additional Comments The minor variance application was circulated to Town Department/Divisions and to external agencies for review and comment. The following comments were provided: Department or Agency Comments Building Division Preliminary Zoning Review was completed August 9, 2022, identifying the non-compliance. Engineering Division  The applicant has provided a site plan showing the built pool’s water edge encroaching 0.286m Page 3 of 17 October 13, 2022 4 of 7 Report No. MV-2022-35 Department or Agency Comments into an existing 1.2m wide Town sewer easement. The neighbouring property to the west also has a 1.8m wide easement, which combined provides a 3.0m easement that allows the Town access to a rear yard catch basin and storm lead located on the adjacent property. The catch basin lead drains to Corner Ridge Road.  In the future the Town may need to complete maintenance, repairs or replacement of the rear yard catch basin or lead and will need to be able to access this infrastructure to complete the works.  The Engineering Division is not aware of any drainage complaints because of the pool encroachment. We believe the function of the rear yard catch basin and its lead are currently not impacted by the pool encroachment. Based on the above Engineering Division has no objections with the above noted application with the following condition:  That if the Committee of adjustment approves this minor variance application that it be approved with a condition that the property owner enter into an agreement with the Town noting that: o the minor variance approval does not limit or alter the Town’s existing easement agreement rights; o the property owner will be required to remove any structures and obstructions from the easement lands at any time that such lands are required by the Town to exercise its easement rights, with the removal of any such encroachments and restoration works being the Page 4 of 17 October 13, 2022 5 of 7 Report No. MV-2022-35 Department or Agency Comments responsibility and at the cost of the property owner; and o such agreement shall be registered on the property. Operational Services (Parks) No comments received at the time of writing this report. Operational Services (Public Works) No comments received at the time of writing this report. Central York Fire Services No comments received at the time of writing this report. York Region Comments provided stating no comments/concerns with proposed application (dated September 23, 2022) LSRCA No comments received at the time of writing this report. Alectra Comments provided stating no comments/concerns with proposed application (dated September 23, 2022) Public Correspondence Written submissions were not received at the time of writing of this report. Should written submissions be received after the writing of this report, the Secretary Treasurer will provide the submission(s) to Committee members at the meeting. Conclusion Planning staff have reviewed the application with respect to the Section 45(1) of the Planning Act, R.S.O, 1990, c.P.13, as amended, and are of the opinion that the requested variance does meet the four tests and meets the requirements of Section 45(1) of the Planning Act for granting of minor variances. Staff recommend approval of the requested variances subject to the conditions outlined in Appendix ‘A’. Page 5 of 17 October 13, 2022 6 of 7 Report No. MV-2022-35 Attachments Appendix ‘A’ – Recommended Conditions of Approval Appendix ‘B’ – Site Plan Page 6 of 17 October 13, 2022 7 of 7 Report No. MV-2022-35 Appendix ‘A’ – Conditions of Approval 1. That the property owner enter into an agreement with the Town noting that:  the minor variance approval does not limit or alter the Town’s existing easement agreement rights;  the property owner will be required to remove any structures and obstructions from the easement lands at any time that such lands are required by the Town to exercise its easement rights, with the removal of any such encroachments and restoration works being the responsibility and at the cost of the property owner; and  such agreement shall be registered on the property. 2. The owner is responsible for paying any fees associated with entering into an agreement with the Town in accordance to the Town fee By-law, as amended. Page 7 of 17 ²²²²²²PR20220897Aug. 9, 2022TOWN OF AURORA PLANNING & DEVELOPMENT SERVICES BUILDING DIVISIONPERMIT NO.: DATE:PRELIMINARY ZONING REVIEWHana HossainAPPROVED BY:August 21, 2022DATE: TOWN OF AURORAPLANNING AND DEVELOPMENT SERVICESDevelopment Planning DivisionRECEIVEDPage 8 of 17 100 John West Way Aurora, Ontario L4G 6J1 (905) 727-3123 aurora.ca Town of Aurora Committee of Adjustment Report No. MV-202 2 -36 _______________________________________________________________________________________ Subject: Minor Variance Application Constantine Rallis 12 Buchanan Crescent MV-2022-36 Prepared by: Sean Lapenna, Planner, Planning and Development Services Department: Planning and Development Services Date: October 13, 2022 _______________________________________________________________________________________ Application The applicant is requesting relief from the Town’s Comprehensive Zoning By-law 6000- 17, as amended, to facilitate the development of a cabana with a gross floor area of approximately 308.0 ft² (28.6 m²) and a building height of 8.0 ft (2.4 m). The following relief from the requirements of the Town’s Zoning By-law 6000-17, as amended, is requested: a) Section 7.2 of the Zoning By-law requires a minimum exterior side yard setback of 6.0 meters. The applicant is proposing a cabana, which is 2.7 metres to the exterior side yard property line. Background Subject Property and Area Context The subject lands are municipally known as 12 Buchanan Crescent and is a corner lot located east of Yonge Street, south of St. John’s Sideroad and on the east side of Buchanan Crescent. The subject lands currently accommodate an existing two -storey single-detached dwelling with attached two-car garage, an in-ground swimming pool and the existing cabana for which the subject variance has been applied for. The subject lands have an approximate lot area of 569.9 m² (6,134.0 ft²) and a lot frontage of 18.7 m (61.35 ft). Page 9 of 17 October 13, 2022 2 of 7 Report No. MV-2022-36 Proposal The applicant has requested one variance for a reduced exterior side yard setback in order to accommodate an existing one-storey rear yard accessory structure, being a cabana with a gross floor area of approximately 308.0 ft² (28.6 m²) and a building height of 8.0 ft (2.4 m). The Town of Aurora received a complaint regarding the existing cabana which is in non- compliance with the exterior side yard setback requirement of the zoning by-law. In response to this, the owner submitted the subject Minor Variance application in order to bring the structure into compliance. The Town’s Building Division confirmed that a Building Permit would be required. Official Plan The subject property is designated ‘Stable Neighbourhood’ by the Town of Aurora Official Plan. Stable Neighbourhoods are to be protected from incompatible forms of development but are permitted to evolve over time. All new development shall be compatible with its surrounding context. Zoning The subject property is zoned ‘R3 (28) (Detached Third Density Residential Exception Zone)’ under Zoning By-law 6000-17, as amended, which permits Accessory Structures such as cabanas. Preliminary Zoning Review A Preliminary Zoning Review (PZR) has been completed by the Town’s Building Division. The PZR identified the required variance, and no other non-compliance was identified. Applicant’s stated reasons(s) for not complying with the Zoning By-law I was unaware of the zoning by-laws requirements pertaining to corner lot facing road and was under the impression that I was complying by all of the rules and regulations. Unfortunately, I started construction and now unable to move my structure. Planning Comments Planning staff have reviewed the requested variance as per the four tests in section 45(1) of the Planning Act. Page 10 of 17 October 13, 2022 3 of 7 Report No. MV-2022-36 a) The proposed variance meets the general intent of the Official Plan Planning staff are of the opinion that the proposed variance will not negatively impact the character of the neighbourhood. The existing cabana for which the subject variance has been applied is modest in scale. No negative impacts are anticipated to result. It is therefore the opinion of Planning staff that the proposed variance maintains the general intent of the Official Plan. b) The proposed variance meets the general intent of the Zoning By-law The subject lands are zoned ‘R3 (28) (Detached Third Density Residential Exception Zone)’ by the Town of Aurora Zoning By-law #6000-17, as amended where accessory structures such as cabanas are permitted. The subject property is a corner lot and the cabana has been constructed in the north- west corner of the property. The purpose of setback requirements under the by-law is to ensure that adequate separation is provided between buildings on abutting properties. Staff acknowledge that the cabana was constructed closer to the exterior side yard property line than what the By-law allows. Staff however are of the opinion that the requested variance will not result in any conflicts from a building separation standpoint, especially considering that the exterior side yard is not abutting another neighbouring residential property but instead, a public thoroughfare (Buchanan Crescent). In addition to this, the rear yard setback for the cabana (which shares a mutual property line with an adjacent neighbouring property to the north) is being met and does not require minor variance approval. Planning Staff are of the opinion that the proposed minor variance maintains the general intent and purpose of the Zoning By-law. c) The variance is considered desirable for the appropriate development or use of the land The cabana was constructed to serve as an accessory to the owner’s existing in-ground swimming pool located in the rear yard of the property. Planning Staff note that several other properties within the local neighbourhood contain rear yard accessory buildings as well as swimming pools. As such, staff consider the cabana as proposed to be consistent with the surrounding area from a built form and character standpoint. As this is an as built structure, the Town’s Engineering Services Division has requested a site grading plan prepared by a professional engineer or qualified engineering professional confirming that the existing drainage pattern at the property has been maintained and that any changes in the grading due to the site works will not result in any Page 11 of 17 October 13, 2022 4 of 7 Report No. MV-2022-36 adverse impacts on adjacent properties. In addition to this, the Engineering Services Division is also looking to confirm that any roof drain downspout(s) on the proposed structure will be located away from the property line to avoid direct outlet of water onto any adjacent property. As such, Planning Staff have included a condition of approval requiring the owner to submit a site grading plan prepared by a professional engineer or qualified engineering professional demonstrating such, to the satisfaction of the Director of Planning and Development Services. Given the condition which has been added, the nature, scale and location of the cabana, staff have no concerns. Based on the above, staff are of the opinion that permitting the subject variance is an appropriate development and use of the land. d) The variance is considered minor in nature Staff consider the use to be small in scale . The owner has confirmed with staff that the cabana will not include the addition of any windows at all. This is reflected on the submitted floor plan. In addition to this, the cabana itself is also screened by a wooden fence which borders the rear yard, meaning that it is not overly visible from streetscape. As a result, any potential impacts in regards to privacy are mitigated. Although the cabana is located closer to the side yard property line than the by-law permits, staff are of the opinion that given the location, scale and height, that the cabana is not considered to be visually obtrusive. Finally, the cabana is non-habitable space and therefore cannot be utilized as a separate detached residential unit. Staff consider the variance to be minor in nature. The minor variance application was circulated internally and to external agencies for review and comment. The following comments were provided: Department / Agency Comments Provided Engineering Services We have no objection to the above noted variance application provided that a site grading plan prepared by a professional engineer or qualified engineering professional is submitted to the satisfaction of the Director of Planning and Development Services, demonstrating that: 1. The existing drainage pattern shall be maintained and any changes in the grading due the proposed site works shall not cause any adverse impacts on the adjacent neighbouring properties; Page 12 of 17 October 13, 2022 5 of 7 Report No. MV-2022-36 2. Roof drain downspout(s) of the proposed structure shall be located away from the property line to avoid direct outlet of water onto the adjacent property. Building Division Preliminary Zoning Review conducted which identified the subject variance and did not confirm any zoning non- compliance was identified. Accessibility Advisor The Town’s Accessibility Advisor has confirmed that they have no comments on the subject variance application. Traffic Analyst No comments provided at the time of writing of this report. Operational Services - Parks Division No comments provided at the time of writing of this report. Central York Fire Services No comments provided at the time of writing of this report. Legal Services Legal Services has no comments. The Regional Municipality of York The Regional Municipality of York has completed its review of the above minor variance and has no comment. Lake Simcoe Region Conservation Authority No comments provided at the time of writing of this report. Alectra Utilities We have reviewed the proposed Variance application and have no objections to its approval, subject to the following comments: Alectra Utilities (formerly PowerStream) has received and reviewed the proposed Variance Application. This review, however, does not imply any approval of the project or plan. All proposed billboards, signs, and other structures associated with the project or plan must maintain minimum clearances to the existing overhead or underground electrical distribution system as specified by the applicable standards, codes and acts referenced. In the event that construction commences, and the clearance between any component of the work/structure and the adjacent existing overhead and underground electrical distribution system violates the Occupational Health and Safety Act, the customer will be responsible for 100% of the costs associated with Alectra making the work area safe. All construction work will be required to stop until the safe limits of approach can be established. Page 13 of 17 October 13, 2022 6 of 7 Report No. MV-2022-36 In the event construction is completed, and the clearance between the constructed structure and the adjacent existing overhead and underground electrical distribution system violates the any of applicable standards, acts or codes referenced, the customer will be responsible for 100% of Alectra’s cost for any relocation work Public Correspondence The written submissions that were received at the time of writing of this report expressed no objection to the requested variance. A copy of comments received have been provided to the Committee by the Secretary-Treasurer. Any other comments received after the writing of this report will also be provided to the Committee for review. Conclusion Planning staff have reviewed the application with respect to the Section 45(1) of the Planning Act, R.S.O, 1990, c.P.13, as amended, and recommend approval subject to conditions of approval. Staff’s recommendation of approval is based under the premise that the information provided on the submitted plans and application form is accurate. The onus is ultimately on the applicant to demonstrate why they should be granted relief from the requirements of the zoning by-law and how they satisfy the four tests of the Planning Act for the granting of minor variance approval. Please refer to Appendix ‘A’ for the recommended conditions of approval for the requested variance. Attachments Appendix ‘A’ - Recommended Conditions of Approval Appendix ‘B’ - Site Plan & Floor Plan Page 14 of 17 October 13, 2022 7 of 7 Report No. MV-2022-36 Appendix ‘A’ – Recommended Conditions of Approval The following conditions are required to be satisfied should application MV-2022-36 be approved by the Committee of Adjustment: 1. That the variance only applies to the subject property, in substantial conformity with the plan(s) attached as ‘Appendix B’ to this Staff Report and dated September 7, 2022, to the satisfaction of the Director of Planning and Development Services. 2. That the owner at its sole cost and expense provide a report along with a grading and drainage plan prepared by a Professional Engineer demonstrating that the drainage pattern on site has been maintained and the structure and any associated grading work completed at site shall not cause any adverse impacts on the drainage of the adjacent properties, to the satisfaction of the Director of Planning and Development Services. Page 15 of 17 12 BUCHANAN CRES. AURORA, ON EXISTING SWIMMING POOL PROPOSED CABANA STRUCTURE W/ STORAGE, W/R &CHANGE AREA BUCHANAN CRESCENTBUCHANAN CRESCENT2.7 M ± 3.6 M ±1.2 CM ±6.67 M 8.57 M 6.1 M5.45 M ± 5.45 M ±5.45 M ±18.3 M 18.7 M 30.48 M12 BUCHANAN CRES. AURORA, ON PROPOSED CONDITION N.T.S PROPERTY LINEPROPERTY LINE PROPERTY LINE EXISTING SLAB ON GRADE Minimum 1.2 metre setback between proposed cabana and existing swimming pool PR20221023 Sept. 7, 2022 TOWN OF AURORA PLANNING & DEVELOPMENT SERVICES BUILDING DIVISION PERMIT NO.: DATE: PRELIMINARY ZONING REVIEW Ashley VanderwalAPPROVED BY: September 7, 2022DATE: TOWN OF AURORA PLANNING AND DEVELOPMENT SERVICES Development Planning Division RECEIVED Page 16 of 17 Existing 12" Diameter ConcreteFoundation Post Min 7' Deep15 M @ 16"± C/C15 M @ 16"± C/C8" CONCRETE SLABON 8" - 34" CRUSHER RUNGRAVEL COMPACTED.Existing Reinforced Concrete SlabOn Grade, 8" Thick and ±10" Thickat Perimeter. 15M Rebar installedboth ways at ±16" spacing.Sonotube is 7' Deep3 # 15 M Bars.CHANGINGROOMWASHROOMPOOL EQUIPMENT A2"x4" WOOD FRAMING WALLUSE WATER RESISTANT DRYWALLTYPICAL 3 SIDESOPEN SPACEUNDER THE BEAM4-2"x4"Wood Postsecure to plateand beam2"x8" JoistSpaced At 16" .3-2"x 10" wood Beam .58" Plywood completedwith roof shinglesAs Built Slab On GradeSlab 32MPA concrete isover 34" Clear Stone±36" Deep over virgin soil.no cracks found in the slab2"X4" WOOD PLATE BOLTED TOCONCRETE SLAB USING 1/2" WEDGEANCHORS, 3 1/2" MINIMUM EMBEDMENTSPACED AT ±36"34" Clear Stone ±36" DeepVirgin soil.Shingles OverIce&WatershieldOver 34" Plywood.2-2"x 4" Top Plate .Metal Drip Flashing2"x4"Wood wallsecure to top andbottom platesPROJECT No.: 22N-08SCALE: NTSDATE: JULY.2022PAGE: 3 OF 3DRAWN BY: A.SDRAWING NO : S3CABANA DESIGNAT 12 BUCHANAN CRES,AURORA, ON,CHECKED BY: J.SFOUNDATION SLAB (As-Built):FLOOR PLAN:Section A-A :NOTES:-CONSTRUCTION TO BE IN ACCORDANCE WITH THE LATESTEDITION OF ONTARIO BUILDING CODE-WALL TO BE CONSTRUCTED FROM 2"X4" WOOD STUDS SPACED AT @±16" O.C. C/W 2X4 SILL PLATE PLUS 2- 2X4 HEADER-IN MY OPINION AND ENGINEERING JUDGEMENT, THE SUB-GRADEUNDER SLAB ON GRADE WILL SUPPORT THE SLAB AND THEPROPOSED CABANA, CONSTRUCTION OF FOOTINGS WILL HAVENO IMPACT OF THE SLAB ON GRADE, BECAUSE THE SLAB ISRESTING OVER GRAVEL OVER VIRGIN SOIL.-NOTIFY THIS ENGINEER FOR INSPECTIONNamcan Engineering andConstruction Management Ltd.john@namcanengineering.ca416 845 8121J.M. SKAFFAug 18, 2022PR20221023Sept. 7, 2022TOWN OF AURORA PLANNING & DEVELOPMENT SERVICES BUILDING DIVISIONPERMIT NO.: DATE:PRELIMINARY ZONING REVIEWAshley VanderwalAPPROVED BY:Page 17 of 17